verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC200 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC200-08 FRL Unit (GC20008MF1WT)

The AirTAC GC200-08 FRL Unit (GC20008MF1WT) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/4" ports, a 5 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/4"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade5 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$71.65 $79.15Save 9% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GC200-08 drain, gauge and thread option on one page All GC200-08 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GC200-08 FRL Unit (GC20008MF1WT)

The AirTAC GC series is a three-unit air preparation combination: a separate filter, pressure regulator and lubricator that together clean, regulate and oil-mist lubricate compressed air. This GC20008MF1WT is the 200 size with NPT1/4 ports, fitted with the finer 5 um W-grade filter element, a manual drain on the filter bowl, an embedded square pressure gauge scaled in MPa, and the standard regulator with a 0.05-0.9 MPa (7-130 psi) setting range.

It is a genuine AirTAC part rated for compressed air at up to 1.0 MPa (145 psi) working pressure between -5 and 70 C (non-freezing). The GC range steps through 200, 300, 400 and 600 sizes with ports from 1/8 to 1 inch, and drain, filter grade, gauge and thread options to suit the installation. Because flow is published as curves rather than a single rated figure, we confirm the datasheet and sizing on request. This version has NPT ports (the T in the order code) for North American pipe fittings.

AirTAC GC200-08 FRL Unit (GC20008MF1WT) Technical Specifications

ModelAirTAC GC200-08 FRL Unit (GC20008MF1WT)
SeriesGC200 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/4" (NPT thread)
Filtering grade5 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeFitted — square, MPa scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC200-08 FRL Unit (GC20008MF1WT)

GC200G-series F.R.L. combination, 200 body — sets the port range.
08Port size PT1/4". This body offers 06 = PT1/8", 08 = PT1/4".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-08 filter, GR200-08 regulator and GL200-08 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC200 · PT1/4" · 5 µm
One size upGC300
Two-unit equivalentGFC200-08
Build orderFilter → regulator → lubricator

Where the AirTAC GC200-08 FRL Unit (GC20008MF1WT) Is Used

view_module

Electronics pick-and-place modules

Supplying an array of compact pick-and-place modules on an electronics assembly line, where the 5 um W-grade element suits the fine valve and cylinder circuits and the lubricator conditions the actuators.

tune

Paint-line conditioning

Conditioning air ahead of the actuation and atomizing circuits on a paint line, with the finer 5 um grade as specified and the regulator set from the embedded MPa gauge.

handyman

Maintenance-shop test rigs

A tidy three-in-one feed for maintenance-shop outlets and pneumatic test rigs: 5 um filtration, a settable regulator with MPa gauge, and lubrication for the tools connected downstream.

Is the AirTAC GC200-08 FRL Unit (GC20008MF1WT) the Right Station?

Size to air demand first: the 200 body with 1/4 inch NPT ports serves lighter branch lines, and the 300, 400 and 600 sizes above it carry progressively more flow on larger ports. The W in this code selects the 5 um element instead of the standard 40 um grade - choose it where fine downstream valves or instruments are fed, and stay at 40 um for general-purpose circuits. The manual drain needs periodic attention; automatic and differential-pressure drains are the alternatives. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Flow is published as curves, not one rated number, so ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/4" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-08 regulator with a GF200-08 filter on that branch.

AirTAC GC200-08 FRL Unit (GC20008MF1WT) FAQ

Flow for the GC series is published as pressure-drop curves, not as a single rated figure, so there is no one number we can quote. Tell us your line pressure and air demand and we will confirm the correct size and the datasheet figures on request before you order.

The blank position selects the standard 40 um element, which suits general-purpose tool and cylinder circuits; W selects the 5 um grade for finer filtration where precision valves or instruments are downstream. Both are catalogue options on this same GC20008 set, so the choice only changes the code.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GC200-08 FRL Unit (GC20008MF1WT)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GC20008MF1WT and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.