The AirTAC GC200-08 FRL Unit (GC20008MF1WTK) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/4" ports, a 5 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/4"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade5 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$86.58 $94.08Save 7% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GC200-08 drain, gauge and thread option on one page All GC200-08 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GC200-08 FRL Unit (GC20008MF1WTK)

GC20008MF1WTK is an AirTAC G-series three-unit F.R.L. combination: a separate air filter, pressure regulator and lubricator built as one matched set. At size 200 with a NPT1/4 port it conditions compressed air in three stages - a 5 um element strips water and fine particulate, the regulator holds a steady downstream pressure, and the lubricator feeds an oil mist to downstream air tools. The manual drain lets you bleed the filter bowl by hand, the embedded square gauge reads in MPa, and the fitted reverse (check) valve helps hold downstream pressure if the supply dips.

This is a genuine AirTAC part. The G-series spans sizes 200 to 600 with ports from 1/8 to 1 inch, and options across the range include 5 or 40 um filtration, automatic, manual or differential-pressure drains, MPa, psi or bar gauge scales, G (BSPP) and NPT thread variants, and low-pressure regulator types. Flow is published as curves rather than a single rating, so we confirm the datasheet figures for your application on request.

AirTAC GC200-08 FRL Unit (GC20008MF1WTK) Technical Specifications

ModelAirTAC GC200-08 FRL Unit (GC20008MF1WTK)
SeriesGC200 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/4" (NPT thread)
Filtering grade5 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeFitted — square, MPa scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC200-08 FRL Unit (GC20008MF1WTK)

GC200G-series F.R.L. combination, 200 body — sets the port range.
08Port size PT1/4". This body offers 06 = PT1/8", 08 = PT1/4".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-08 filter, GR200-08 regulator and GL200-08 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC200 · PT1/4" · 5 µm
One size upGC300
Two-unit equivalentGFC200-08
Build orderFilter → regulator → lubricator

Where the AirTAC GC200-08 FRL Unit (GC20008MF1WTK) Is Used

precision_manufacturing

Pneumatic press clamping circuit

Feeds filtered, regulated and lubricated air to the clamp cylinders on a workholding press, with the check valve holding clamp pressure if the main supply dips.

air

Assembly bench air tools

A single 1/4 inch drop at an assembly station conditions the supply for impact drivers and ratchets: 5 um filtration, set pressure and oil mist in one unit.

valve

Pilot-air supply to process valves

Conditions the pilot line feeding pneumatic valve positioners and actuators, where clean 5 um air and a stable set pressure protect the control loop.

Is the AirTAC GC200-08 FRL Unit (GC20008MF1WTK) the Right Station?

Size 200 with a 1/4 inch port suits compact tool circuits and small actuator lines; if your air demand grows, step up to GC300/400/600 for larger ports and higher flow capacity. The manual drain here is the right pick where the unit is easy to reach on a maintenance walk; choose automatic or differential-pressure drains if bowls sit in awkward spots. The 5 um (W) element is the finer choice over the 40 um standard when downstream valves and cylinders need cleaner air.

The square embedded gauge reads in MPa; psi and bar scales and an external round gauge are catalogue alternatives. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Because flow is published as curves, not one rated number, send us your flow and pressure requirements and we will confirm sizing against the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT1/4" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-08 regulator with a GF200-08 filter on that branch.

AirTAC GC200-08 FRL Unit (GC20008MF1WTK) FAQ

AirTAC publishes flow for the G-series as curves, not as a single rated figure, so we do not quote a number here. Tell us your required flow and working pressure and we will confirm the datasheet curve values for the GC200 size before you order.

The W code in GC20008MF1WTK selects the 5 um element instead of the 40 um standard grade. The finer element removes smaller particulate and water carryover, which suits precision valves, cylinders and air tools; the standard 40 um grade remains available on other GC codes.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GC200-08 FRL Unit (GC20008MF1WTK)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GC20008MF1WTK and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.