AirTAC GC200 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC200-08 FRL Unit (GC20008MF3T)

The AirTAC GC200-08 FRL Unit (GC20008MF3T) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/4" ports, a 40 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/4"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade40 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$71.65 $79.15Save 9% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GC200-08 drain, gauge and thread option on one page All GC200-08 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GC200-08 FRL Unit (GC20008MF3T)

GC20008MF3T is an AirTAC G-series three-unit F.R.L. combination: a separate filter, regulator and lubricator supplied as one matched set. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. The filter bowl carries a manual drain, and the embedded square gauge reads in bar to suit metric-spec machinery and European-style drawings.

This is a genuine AirTAC part. The G-series covers sizes 200 to 600 with ports from 1/8 to 1 inch; across the range you can order 5 um fine filtration, automatic or differential-pressure drains, MPa, psi or bar gauge scales, G (BSPP) and NPT threads, and a low-pressure regulator type. Flow appears in the catalogue as curves rather than a single rating, so we confirm datasheet figures for your application on request.

AirTAC GC200-08 FRL Unit (GC20008MF3T) Technical Specifications

ModelAirTAC GC200-08 FRL Unit (GC20008MF3T)
SeriesGC200 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/4" (NPT thread)
Filtering grade40 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeFitted — square, bar scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC200-08 FRL Unit (GC20008MF3T)

GC200G-series F.R.L. combination, 200 body — sets the port range.
08Port size PT1/4". This body offers 06 = PT1/8", 08 = PT1/4".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
3Gauge scale: bar. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-08 filter, GR200-08 regulator and GL200-08 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC200 · PT1/4" · 40 µm
One size upGC300
Two-unit equivalentGFC200-08
Build orderFilter → regulator → lubricator

Where the AirTAC GC200-08 FRL Unit (GC20008MF3T) Is Used

factory

Textile machine air prep

Conditions the machine-air feed on looms and winding heads, where the bar-scaled gauge matches the metric pressure settings on the machine datasheet.

conveyor_belt

Conveyor actuator supply

Filters, regulates and lubricates the air feeding conveyor diverters, gate cylinders and hold-down clamps on a packaging or sorting line.

handyman

Workshop multi-station header

Installed upstream of a 1/4 inch manifold that serves several air tools and blow-off points in a general repair workshop.

Is the AirTAC GC200-08 FRL Unit (GC20008MF3T) the Right Station?

Size 200 with the 1/4 inch port is the compact step of the range - move to GC300/400/600 when larger ports and higher flow are needed. The 40 um standard element suits general machine air; select a W-code 5 um set where finer filtration is required. The manual drain suits bowls that are checked on a routine walk; automatic and differential-pressure drain codes exist for unmanned or awkward locations.

This version's square embedded gauge is scaled in bar; MPa and psi scales are alternative codes. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Since flow is published as curves rather than a single rated number, ask us to check your required flow and pressure against the datasheet before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/4" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-08 regulator with a GF200-08 filter on that branch.

AirTAC GC200-08 FRL Unit (GC20008MF3T) FAQ

G-series flow is published as curves, not as a single rated figure, so we do not quote a number here. Give us your required flow and upstream pressure and we will confirm the applicable datasheet curve values for the GC200 size on request.

The M code here is a manual drain: someone bleeds the filter bowl by hand, which suits accessible installations on a maintenance route. If the set will sit in an unmanned or hard-to-reach spot, choose an automatic (A) or differential-pressure (blank) drain code instead.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GC200-08 FRL Unit (GC20008MF3T)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GC20008MF3T and will confirm price, availability and lead time — usually within 7 hours.