verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC200 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC200-08 FRL Unit (GC20008MLF1T)

The AirTAC GC200-08 FRL Unit (GC20008MLF1T) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/4" ports, a 40 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/4"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade40 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$71.65 $79.15Save 9% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GC200-08 drain, gauge and thread option on one page All GC200-08 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GC200-08 FRL Unit (GC20008MLF1T)

The GC series is AirTAC's three-unit F.R.L. combination: a separate air filter, a pressure regulator and a lubricator assembled as one set, so the compressed air stream is cleaned, regulated and oil-mist lubricated in sequence. This GC200 size is fitted with 1/4 in. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. The filter and lubricator bowls are polycarbonate on the 200 size.

This is a genuine AirTAC part. The G series spans 200, 300, 400 and 600 sizes with 1/8 in. to 1 in. ports, and is offered with your choice of drain type, filter grade, gauge style and scale, and three thread types (NPT on this code). Maximum working pressure is 1.0 MPa (145 psi) and the temperature range is -5 to 70 C, non-freezing. Flow is published as curves rather than a single rating, so we confirm flow and datasheet figures for your application on request. Order code GC20008MLF1T has NPT ports (the T in the code) for North American pipe fittings.

AirTAC GC200-08 FRL Unit (GC20008MLF1T) Technical Specifications

ModelAirTAC GC200-08 FRL Unit (GC20008MLF1T)
SeriesGC200 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/4" (NPT thread)
Filtering grade40 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeFitted — square, MPa scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC200-08 FRL Unit (GC20008MLF1T)

GC200G-series F.R.L. combination, 200 body — sets the port range.
08Port size PT1/4". This body offers 06 = PT1/8", 08 = PT1/4".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-08 filter, GR200-08 regulator and GL200-08 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC200 · PT1/4" · 40 µm
One size upGC300
Two-unit equivalentGFC200-08
Build orderFilter → regulator → lubricator

Where the AirTAC GC200-08 FRL Unit (GC20008MLF1T) Is Used

conveyor_belt

Conveyor line guide and gate cylinders

Conditions the air feeding guide rails, stops and gate actuators along a packaging or sorting conveyor, with general-purpose 40 um filtration and lubrication sized for a 1/4 in. branch circuit.

view_module

Modular pick-and-place station air supply

One compact F.R.L. point feeding multiple valve islands and small gripper cylinders on an automation module, with the square MPa gauge built into the regulator face for setpoint checks.

local_shipping

Trailer and dock-equipment air circuits

Filters, regulates and lubricates the air supply to dock leveller controls and door actuator circuits at a loading bay, where manual drain suits a scheduled maintenance round.

Is the AirTAC GC200-08 FRL Unit (GC20008MLF1T) the Right Station?

This code carries the standard 40 um element - a good general-purpose choice for shop air feeding cylinders and valves - with the 5 um W option available where finer filtration is needed. The 200 size with 1/4 in. NPT ports is the compact step in the G series; move to GC300/GC400 for larger ports and higher flow. Drain is manual, so bowl draining is a routine operator task; differential-pressure and automatic drains are available in the same position. The gauge is the embedded square type in MPa scale; the external round gauge and psi/bar scales are catalogue alternatives. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes.

Flow is published as curves, not a single rated figure, so ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/4" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-08 regulator with a GF200-08 filter on that branch.

AirTAC GC200-08 FRL Unit (GC20008MLF1T) FAQ

No single rated flow figure exists for this unit in the catalogue - AirTAC publishes flow as performance curves. We will gladly confirm the flow and datasheet figures against your application on request, and advise whether the 200 size or a 300/400 step-up is the right match.

The blank filter-grade position in the code is the standard 40 um element, which suits general shop air feeding cylinders and directional valves. If your equipment needs finer air, order the same set with W in that position (for example GC20008MLF1W) for the 5 um element.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GC200-08 FRL Unit (GC20008MLF1T)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GC20008MLF1T and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.