The AirTAC GC200-08 FRL Unit (GC20008MLF1WTK) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/4" ports, a 5 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).
GC20008MLF1WTK is an AirTAC GC-series three-unit F.R.L. set for compressed air: a separate filter, pressure regulator and lubricator working together. This 200-size configuration is decoded with a NPT1/4 (1/4 inch) port, a manual drain on the filter bowl, the 5 um filter element (W option), the low-pressure regulator type, an embedded square gauge on a MPa scale, and a reverse (check) valve fitted so downstream air cannot flow back toward the supply. The filter and lubricator bowls on this 200 size are polycarbonate (PC).
This is a genuine AirTAC part. The GC series is also available in 300, 400 and 600 sizes with larger ports, a choice of differential-pressure, automatic or manual drain, 40 um standard or 5 um filtration, standard or low-pressure regulation, gauge options with MPa, psi or bar scales, and G (BSPP) or NPT threads in place of the NPT standard. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing. Flow is published as curves rather than a single rating, so we confirm datasheet and sizing figures on request.
| Model | AirTAC GC200-08 FRL Unit (GC20008MLF1WTK) |
|---|---|
| Series | GC200 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | PT1/4" (NPT thread) |
| Filtering grade | 5 µm |
| Regulating range | 0.05 - 0.9 MPa (7 - 130 psi) |
| Pressure type | Low-pressure type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Manual drain |
| Bowl material | PC |
| Pressure gauge | Fitted — square, MPa scale |
| Reflux valve | Fitted (reverse flow permitted) |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC200 | G-series F.R.L. combination, 200 body — sets the port range. |
|---|---|
| 08 | Port size PT1/4". This body offers 06 = PT1/8", 08 = PT1/4". |
| M | Drain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)). |
| L | Low-pressure type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 1 | Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar. |
| W | Filtering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| K | Reverse-flow (reflux) valve fitted. |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-08 filter, GR200-08 regulator and GL200-08 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC200 · PT1/4" · 5 µm |
|---|---|
| One size up | GC300 |
| Two-unit equivalent | GFC200-08 |
| Build order | Filter → regulator → lubricator |
Feeding the directional valve bank of a carton-forming packaging machine with filtered, lubricated air at a stable low set pressure, with the square MPa gauge visible on the panel and the reverse valve holding downstream pressure.
Supplying a bench-mounted pneumatic press cell where a low set pressure, clean 5 um air and an at-a-glance pressure readout support consistent, operator-controlled cycles.
Running small vane air motors on agitators, stirrers or turntables with clean, lubricated air regulated to a low set pressure and monitored on the MPa gauge.
The GC range steps through 200, 300, 400 and 600 sizes; this 200 set with its 1/4 inch NPT port suits lighter branch lines, and moving up a size gives more flow where demand is higher. Drain is manual (M) in this code; automatic and differential-pressure drains are catalogue options if you would rather not drain the bowl by hand. The W code selects the 5 um element over the 40 um standard, L selects the low-pressure regulator type (confirm its exact adjustment range with us), F1 gives the embedded square gauge on a MPa scale, and K fits a reverse valve. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes.
Because AirTAC publishes flow for this series as curves, not a single rated number, ask us to confirm sizing against your line pressure and downstream demand before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-08 regulator with a GF200-08 filter on that branch.
AirTAC publishes flow for this series as curves rather than a single rated figure, so we do not quote one number here. Send us your line pressure, downstream demand and allowed pressure drop, and we will confirm the sizing and the datasheet on request.
It means a reverse (check) valve is fitted, so air cannot flow back through the set toward the regulator. Sets without the K are ordered without a check valve; ask us if you need that option either way.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.