The AirTAC GC200-08 FRL Unit (GC20008MNT) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/4" ports, a 40 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).
GC20008MNT is an AirTAC GC-series three-unit F.R.L. set for compressed air: a separate filter, pressure regulator and lubricator supplied as three units. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. It is ordered without a gauge, and the filter and lubricator bowls on this 200 size are polycarbonate (PC).
This is a genuine AirTAC part. The GC series is also available in 300, 400 and 600 sizes with larger ports, differential-pressure, automatic or manual drain, 40 um standard or 5 um (W) filtration, standard or low-pressure regulation, embedded square or external round gauges with MPa, psi or bar scales, and G (BSPP) or NPT threads in place of the NPT standard. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing. Flow is published as curves rather than a single rating, so we confirm datasheet and sizing figures on request.
| Model | AirTAC GC200-08 FRL Unit (GC20008MNT) |
|---|---|
| Series | GC200 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | PT1/4" (NPT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.05 - 0.9 MPa (7 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Manual drain |
| Bowl material | PC |
| Pressure gauge | Not fitted |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC200 | G-series F.R.L. combination, 200 body — sets the port range. |
|---|---|
| 08 | Port size PT1/4". This body offers 06 = PT1/8", 08 = PT1/4". |
| M | Drain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| N | No pressure gauge (N). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-08 filter, GR200-08 regulator and GL200-08 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC200 · PT1/4" · 40 µm |
|---|---|
| One size up | GC300 |
| Two-unit equivalent | GFC200-08 |
| Build order | Filter → regulator → lubricator |
Driving quarter-turn pneumatic actuators on plant valves, with the standard regulator trimming pressure across its 0.05-0.9 MPa (7-130 psi) range and lubricated air protecting the actuator seals.
Running cylinders on dock levellers and industrial door drives where general-purpose 40 um filtration, regulated pressure and an oil mist keep seals healthy in daily use.
Supplying cylinders and clamps on a general production line where the standard regulator type, not a low-pressure trim, is the right decode for the machine's set points.
In the GC range of 200, 300, 400 and 600 sizes, this 200 set with its 1/4 inch NPT port fits lighter branch lines; step up a size where demand needs more flow. Drain is manual (M) and the regulator is the standard type with a 0.05-0.9 MPa (7-130 psi) adjustment range; the L-coded low-pressure type is an option where lower set pressures are the job. The element is the 40 um standard (5 um is the W option) and N means no gauge, though square or round gauges are available on equivalent codes. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes.
Flow for the series is published as curves, not a single rated number, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-08 regulator with a GF200-08 filter on that branch.
AirTAC publishes flow for this series as curves rather than a single rated figure, so we do not quote one number here. Send us your line pressure, downstream demand and allowed pressure drop, and we will confirm the sizing and the datasheet on request.
Yes. The N in the code means this set is ordered without a gauge. Embedded square gauges with MPa, psi or bar scales, and external round gauges, are catalogue options on the same series - we can quote the equivalent gauge-fitted code.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.