verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC200 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC200-08 FRL Unit (GC20008MNT)

The AirTAC GC200-08 FRL Unit (GC20008MNT) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/4" ports, a 40 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/4"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade40 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeNot fitted
  • ThreadNPT
$64.12 $71.62Save 10% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GC200-08 drain, gauge and thread option on one page All GC200-08 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GC200-08 FRL Unit (GC20008MNT)

GC20008MNT is an AirTAC GC-series three-unit F.R.L. set for compressed air: a separate filter, pressure regulator and lubricator supplied as three units. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. It is ordered without a gauge, and the filter and lubricator bowls on this 200 size are polycarbonate (PC).

This is a genuine AirTAC part. The GC series is also available in 300, 400 and 600 sizes with larger ports, differential-pressure, automatic or manual drain, 40 um standard or 5 um (W) filtration, standard or low-pressure regulation, embedded square or external round gauges with MPa, psi or bar scales, and G (BSPP) or NPT threads in place of the NPT standard. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing. Flow is published as curves rather than a single rating, so we confirm datasheet and sizing figures on request.

AirTAC GC200-08 FRL Unit (GC20008MNT) Technical Specifications

ModelAirTAC GC200-08 FRL Unit (GC20008MNT)
SeriesGC200 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/4" (NPT thread)
Filtering grade40 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeNot fitted
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC200-08 FRL Unit (GC20008MNT)

GC200G-series F.R.L. combination, 200 body — sets the port range.
08Port size PT1/4". This body offers 06 = PT1/8", 08 = PT1/4".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
NNo pressure gauge (N).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-08 filter, GR200-08 regulator and GL200-08 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC200 · PT1/4" · 40 µm
One size upGC300
Two-unit equivalentGFC200-08
Build orderFilter → regulator → lubricator

Where the AirTAC GC200-08 FRL Unit (GC20008MNT) Is Used

valve

Process valve actuation

Driving quarter-turn pneumatic actuators on plant valves, with the standard regulator trimming pressure across its 0.05-0.9 MPa (7-130 psi) range and lubricated air protecting the actuator seals.

local_shipping

Dock and door equipment

Running cylinders on dock levellers and industrial door drives where general-purpose 40 um filtration, regulated pressure and an oil mist keep seals healthy in daily use.

factory

General machine actuation

Supplying cylinders and clamps on a general production line where the standard regulator type, not a low-pressure trim, is the right decode for the machine's set points.

Is the AirTAC GC200-08 FRL Unit (GC20008MNT) the Right Station?

In the GC range of 200, 300, 400 and 600 sizes, this 200 set with its 1/4 inch NPT port fits lighter branch lines; step up a size where demand needs more flow. Drain is manual (M) and the regulator is the standard type with a 0.05-0.9 MPa (7-130 psi) adjustment range; the L-coded low-pressure type is an option where lower set pressures are the job. The element is the 40 um standard (5 um is the W option) and N means no gauge, though square or round gauges are available on equivalent codes. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes.

Flow for the series is published as curves, not a single rated number, so ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/4" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-08 regulator with a GF200-08 filter on that branch.

AirTAC GC200-08 FRL Unit (GC20008MNT) FAQ

AirTAC publishes flow for this series as curves rather than a single rated figure, so we do not quote one number here. Send us your line pressure, downstream demand and allowed pressure drop, and we will confirm the sizing and the datasheet on request.

Yes. The N in the code means this set is ordered without a gauge. Embedded square gauges with MPa, psi or bar scales, and external round gauges, are catalogue options on the same series - we can quote the equivalent gauge-fitted code.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GC200-08 FRL Unit (GC20008MNT)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GC20008MNT and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.