
The AirTAC GC200-08 FRL Unit (GC20008MNTK) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/4" ports, a 40 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).
GC20008MNTK is a genuine AirTAC G-series three-unit F.R.L. combination - separate filter, regulator and lubricator - in size 200 with NPT1/4 (1/4 in.) ports. This configuration has a manual drain on the filter bowl, a standard 40 um filter element and a fitted reverse (check) valve, and is ordered without a gauge, so downstream pressure is set with your own gauge or to a known setting. The manual-drain regulator covers 0.05-0.9 MPa (7-130 psi); the 200-size bowls are polycarbonate (PC).
Maximum working pressure is 1.0 MPa (145 psi) and the working range is -5 to 70 C, non-freezing, with compressed air as the only medium. The G-series spans sizes 200 to 600 with ports from 1/8 to 1 in., three thread types (NPT on this code), a choice of drain types and 40 um or 5 um elements. Flow is published as curves, not a single rating, so we confirm datasheet figures on request.
| Model | AirTAC GC200-08 FRL Unit (GC20008MNTK) |
|---|---|
| Series | GC200 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | PT1/4" (NPT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.05 - 0.9 MPa (7 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Manual drain |
| Bowl material | PC |
| Pressure gauge | Not fitted |
| Reflux valve | Fitted (reverse flow permitted) |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC200 | G-series F.R.L. combination, 200 body — sets the port range. |
|---|---|
| 08 | Port size PT1/4". This body offers 06 = PT1/8", 08 = PT1/4". |
| M | Drain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| N | No pressure gauge (N). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| K | Reverse-flow (reflux) valve fitted. |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-08 filter, GR200-08 regulator and GL200-08 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC200 · PT1/4" · 40 µm |
|---|---|
| One size up | GC300 |
| Two-unit equivalent | GFC200-08 |
| Build order | Filter → regulator → lubricator |
Conditioning the 1/4 in. supply to a machining centre's tool-changer cylinder, where the fitted check valve holds the line during supply dips and the manual drain is emptied at shift start.
Feeding reject diverters and stamping cylinders on a carton packing line: filtered, regulated and oiled NPT1/4 air keeps pipe scale out of the valve seats on a manned line.
A maintenance bench take-off for impact wrenches and air ratchets - one NPT1/4 point delivering clean, regulated, lubricated air, drained by hand at the end of each shift.
Size 200 with NPT1/4 suits 1/4 in. branches and small cylinders; step up to 300, 400 or 600 if your line and flow demand a larger port. This code pairs a manual drain (empty the bowl by hand as part of a routine) with the 40 um standard element - choose the W variant for 5 um, or automatic draining if nobody is on site to drain. The K in the code adds the reverse (check) valve, and N means no gauge; This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Flow is published as curves rather than a single rating, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-08 regulator with a GF200-08 filter on that branch.
AirTAC publishes G-series flow as curves against pressure rather than a single rated figure, so we do not quote a number here. Send us your line size and duty and we will confirm the flow curve and full datasheet figures for this unit on request.
The N in GC20008MNTK specifies the set without a gauge. If you want one built in, order the equivalent code with a gauge designation: the standard option is the embedded square gauge, with an external round gauge optional, scaled in MPa (1), psi (2) or bar (3).
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.