AirTAC GC200 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC200-08 FRL Unit (GC20008MNWTK)

The AirTAC GC200-08 FRL Unit (GC20008MNWTK) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/4" ports, a 5 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/4"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade5 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeNot fitted
  • ThreadNPT
$78.78 $86.28Save 8% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GC200-08 drain, gauge and thread option on one page All GC200-08 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GC200-08 FRL Unit (GC20008MNWTK)

GC20008MNWTK is a genuine AirTAC G-series three-unit F.R.L. combination - separate filter, regulator and lubricator - in size 200 with NPT1/4 (1/4 in.) ports. This configuration has a manual drain on the filter bowl, the 5 um fine filter element (W instead of the 40 um standard) and a fitted reverse (check) valve (K), and is ordered without a gauge, so downstream pressure is set with your own gauge or to a known setting. The manual-drain regulator covers 0.05-0.9 MPa (7-130 psi); the 200-size bowls are polycarbonate (PC).

Maximum working pressure is 1.0 MPa (145 psi) and the working range is -5 to 70 C, non-freezing, with compressed air as the only medium. The G-series spans sizes 200 to 600 with ports from 1/8 to 1 in., three thread types (NPT on this code), a choice of drain types and 40 um or 5 um elements. Flow is published as curves, not a single rating, so we confirm datasheet figures on request.

AirTAC GC200-08 FRL Unit (GC20008MNWTK) Technical Specifications

ModelAirTAC GC200-08 FRL Unit (GC20008MNWTK)
SeriesGC200 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/4" (NPT thread)
Filtering grade5 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeNot fitted
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC200-08 FRL Unit (GC20008MNWTK)

GC200G-series F.R.L. combination, 200 body — sets the port range.
08Port size PT1/4". This body offers 06 = PT1/8", 08 = PT1/4".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
NNo pressure gauge (N).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-08 filter, GR200-08 regulator and GL200-08 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC200 · PT1/4" · 5 µm
One size upGC300
Two-unit equivalentGFC200-08
Build orderFilter → regulator → lubricator

Where the AirTAC GC200-08 FRL Unit (GC20008MNWTK) Is Used

valve

Pilot-air stand-by for process valves

Supplying pilot air to automated process valves on a skid, where the check valve holds the conditioned pilot line during supply interruptions and 5 um filtration protects the pilot ports.

engineering

Robot gripper stand-by circuit

Conditioning the 1/4 in. feed to a robot gripper circuit that must not lose position on an air dip - the fitted check valve plus filtered, regulated, lubricated air in one NPT1/4 set.

handyman

Mould-shop clamp circuit

Feeding small clamping cylinders on injection-mould auxiliary tooling, with the 5 um element guarding fine valves and the manual drain emptied as part of the mould-change routine.

Is the AirTAC GC200-08 FRL Unit (GC20008MNWTK) the Right Station?

Size 200 with NPT1/4 suits 1/4 in. branches and small actuators; step up to 300, 400 or 600 where the line and flow demand a larger port. This code pairs a manual drain with the 5 um element and adds the K reverse (check) valve - leave K out if you do not want the valve, and choose 40 um or automatic draining where they suit better. N means no gauge; This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Flow is published as curves rather than a single rating, so ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/4" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-08 regulator with a GF200-08 filter on that branch.

AirTAC GC200-08 FRL Unit (GC20008MNWTK) FAQ

AirTAC publishes G-series flow as curves against pressure rather than a single rated figure, so we do not quote a number here. Send us your line size and duty and we will confirm the flow curve and full datasheet figures for this unit on request.

K specifies that a reverse (check) valve is fitted to this unit; the same set without the valve simply omits the K. It is one of the decodable G-series options, alongside drain type, filter grade, gauge and thread.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GC200-08 FRL Unit (GC20008MNWTK)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GC20008MNWTK and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.