The AirTAC GC200-08 FRL Unit (GC20008NT) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/4" ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
GC20008NT is a genuine AirTAC G-series three-unit F.R.L. combination - separate filter, regulator and lubricator - in size 200 with NPT1/4 (1/4 in.) ports. The blank drain position selects the differential-pressure drain, so no drain letter is fitted and no manual routine is needed; the filter element is the 40 um standard, and N specifies the set without a gauge, so downstream pressure is set with your own gauge or to a known setting. The differential-drain regulator covers 0.15-0.9 MPa (20-130 psi); the 200-size bowls are polycarbonate (PC).
Maximum working pressure is 1.0 MPa (145 psi) and the working range is -5 to 70 C, non-freezing, with compressed air as the only medium. The G-series spans sizes 200 to 600 with ports from 1/8 to 1 in., three thread types (NPT on this code), a choice of drain types and 40 um or 5 um elements. Flow is published as curves, not a single rating, so we confirm datasheet figures on request.
| Model | AirTAC GC200-08 FRL Unit (GC20008NT) |
|---|---|
| Series | GC200 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | PT1/4" (NPT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Not fitted |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC200 | G-series F.R.L. combination, 200 body — sets the port range. |
|---|---|
| 08 | Port size PT1/4". This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| N | No pressure gauge (N). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-08 filter, GR200-08 regulator and GL200-08 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC200 · PT1/4" · 40 µm |
|---|---|
| One size up | GC300 |
| Two-unit equivalent | GFC200-08 |
| Build order | Filter → regulator → lubricator |
A wall-mounted NPT1/4 drop feeding air vices and small clamps at a machining cell, with the differential-pressure drain handling condensate on an unattended line and the 40 um element catching pipe scale.
Conditioning the 1/4 in. supply to dock-leveller and door-actuation valves in a warehouse, where set-and-forget differential draining suits equipment nobody drains by hand.
Supplying short air-blow nozzles that clear containers on a bottling filling line - filtered, regulated and lubricated air from one NPT1/4 combination set with no gauge in the panel.
Size 200 with NPT1/4 suits 1/4 in. branches and small actuators; step up to 300, 400 or 600 where the line and flow demand a larger port. This code leaves the drain position blank, which selects the differential-pressure drain and the 40 um standard element - add M for manual draining, A for automatic, or W for 5 um filtration. N means no gauge; This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Flow is published as curves rather than a single rating, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-08 regulator with a GF200-08 filter on that branch.
AirTAC publishes G-series flow as curves against pressure rather than a single rated figure, so we do not quote a number here. Send us your line size and duty and we will confirm the flow curve and full datasheet figures for this unit on request.
A blank drain position selects the differential-pressure drain, which is the G-series default. The catalogue alternatives are M for a manual drain (regulator range then 0.05-0.9 MPa / 7-130 psi instead of 0.15-0.9 MPa / 20-130 psi) and A for an automatic drain - choose by how the installation is attended.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.