AirTAC GC300 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC300-08 FRL Unit (GC30008AC1TK)

The AirTAC GC300-08 FRL Unit (GC30008AC1TK) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/4" ports, a 40 µm element, a automatic drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/4"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainAutomatic drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$136.04 $143.54Save 5% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GC300-08 drain, gauge and thread option on one page All GC300-08 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GC300-08 FRL Unit (GC30008AC1TK)

GC30008AC1TK is a genuine AirTAC GC three-unit F.R.L. combination: a separate GF air filter, GR pressure regulator and GL lubricator assembled into one conditioned-air train, with a reverse (check) valve fitted. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. The polycarbonate bowls are rated for compressed air at up to 1.0 MPa (145 psi) inlet and -5 to 70 C, and the regulator adjusts from 0.15 to 0.9 MPa (20-130 psi).

The GC series is offered in 200, 300, 400 and 600 sizes with ports from 1/8 in to 1 in, 40 um standard or 5 um (W) elements, differential-pressure, automatic or manual drains, embedded square or round external gauges scaled in MPa, psi or bar, and three thread types (NPT on this code). AirTAC publishes flow for these units as characteristic curves rather than a single rated figure, so ask us to confirm the datasheet and sizing for your application.

AirTAC GC300-08 FRL Unit (GC30008AC1TK) Technical Specifications

ModelAirTAC GC300-08 FRL Unit (GC30008AC1TK)
SeriesGC300 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/4" (NPT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeAutomatic drain
Bowl materialPC
Pressure gaugeFitted — round, MPa scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC300-08 FRL Unit (GC30008AC1TK)

GC300G-series F.R.L. combination, 300 body — sets the port range.
08Port size PT1/4". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
ADrain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-08 filter, GR300-08 regulator and GL300-08 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC300 · PT1/4" · 40 µm
One size downGC200
One size upGC400
Two-unit equivalentGFC300-08
Build orderFilter → regulator → lubricator

Where the AirTAC GC300-08 FRL Unit (GC30008AC1TK) Is Used

handyman

Nailer and stapler station

Feeds the pneumatic nailers and staplers at a furniture-shop bench with filtered, regulated and lubricated air; the oil mist conditions the tool motors stroke after stroke.

speed

Form-fill-seal machine motions

Conditions the air driving the sealing-jaw and product-push cylinders on a form-fill-seal packaging machine, with the round MPa gauge giving the setter a local pressure reading.

engineering

Vertical lift cylinder on a stacking station

Supplies the lift cylinder on a small stacking station; the fitted check valve blocks the load-side pressure from backing up toward the regulator when supply pressure drops.

Is the AirTAC GC300-08 FRL Unit (GC30008AC1TK) the Right Station?

This code matches the GC30008AC1 set - 300 size, NPT1/4, automatic drain, 40 um element, round MPa gauge - and adds the K option: a reverse (check) valve that blocks downstream pressure from pushing back toward the regulator if supply pressure falls. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes.

Flow is published as curves, not a single rating, so send us your pressure and consumption points and we will confirm sizing against the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT1/4" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-08 regulator with a GF300-08 filter on that branch.

AirTAC GC300-08 FRL Unit (GC30008AC1TK) FAQ

AirTAC publishes GC flow as characteristic curves rather than a single rated figure, so there is no single l/min number to state. Share your working pressure and required flow and we will confirm sizing from the datasheet on request.

K marks that a reverse (check) valve is fitted to the set, blocking downstream pressure from pushing back toward the regulator when supply pressure falls. The same code without the K is supplied without the valve.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GC300-08 FRL Unit (GC30008AC1TK)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GC30008AC1TK and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.