The AirTAC GC300-08 FRL Unit (GC30008AC2T) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/4" ports, a 40 µm element, a automatic drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/4"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainAutomatic drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$121.11 $128.61Save 5% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GC300-08 drain, gauge and thread option on one page All GC300-08 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GC300-08 FRL Unit (GC30008AC2T)

The GC series combines three separate units - air filter, pressure regulator and lubricator - into one F.R.L. set. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. A round external pressure gauge on psi scale is included, and there is no reverse valve in the air path. With automatic drain, the regulator adjusts from 0.15 to 0.9 MPa (20 to 130 psi).

This is a genuine AirTAC part. Maximum working pressure is 1.0 MPa (145 psi), working temperature is -5 to 70 C (non-freezing), and the bowls are polycarbonate (PC) at this size. The G series is available in sizes 200, 300, 400 and 600 with a range of drain, element, gauge, thread and bracket options. Flow is published as curves rather than a single rating - ask us to confirm the datasheet figures on request. Order code GC30008AC2T has NPT ports (the T in the code) for North American pipe fittings.

AirTAC GC300-08 FRL Unit (GC30008AC2T) Technical Specifications

ModelAirTAC GC300-08 FRL Unit (GC30008AC2T)
SeriesGC300 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/4" (NPT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeAutomatic drain
Bowl materialPC
Pressure gaugeFitted — round, psi scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC300-08 FRL Unit (GC30008AC2T)

GC300G-series F.R.L. combination, 300 body — sets the port range.
08Port size PT1/4". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
ADrain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-08 filter, GR300-08 regulator and GL300-08 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC300 · PT1/4" · 40 µm
One size downGC200
One size upGC400
Two-unit equivalentGFC300-08
Build orderFilter → regulator → lubricator

Where the AirTAC GC300-08 FRL Unit (GC30008AC2T) Is Used

factory

Pneumatic bench press cell

Feeds a pneumatic assembly press with filtered, regulated and lightly lubricated shop air, with the automatic drain keeping condensate out of the cylinder supply across the shift.

conveyor_belt

Bottling line actuators

Conditions the air serving filler, capper and rejector cylinders on a bottling conveyor, giving the machine one set pressure and one lubrication point instead of tuning each drop separately.

handyman

MRO workshop air drop

Provides a regulated, filtered and lubricated supply at a maintenance workshop bench, powering impact tools, clamps and test rigs from a single 1/4 in NPT connection.

Is the AirTAC GC300-08 FRL Unit (GC30008AC2T) the Right Station?

Choose size 300 / 1/4 in NPT when your line's flow and porting sit in the mid range; sizes 200, 400 and 600 cover smaller and larger steps. Drain is automatic here - M gives manual draining and a blank position gives the differential-pressure default. The 40 um element is the standard grade; specify W for the 5 um fine element. The C2 code selects a round gauge reading in psi; MPa (C1) and bar (C3) scales are also catalogue choices. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Flow appears in the catalogue as curves, not a single rating, so ask us to check sizing against your application before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT1/4" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-08 regulator with a GF300-08 filter on that branch.

AirTAC GC300-08 FRL Unit (GC30008AC2T) FAQ

Flow for the G series is published as curves rather than a single rated figure, so we do not state one number here. Tell us your application and we will confirm the datasheet flow curve and sizing for GC30008AC2T on request.

The C2 code selects a round external pressure gauge reading in psi. C1 is MPa and C3 is bar, while the configuration with no gauge code at all uses the embedded square gauge. These are catalogue code choices, not additions made later.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GC300-08 FRL Unit (GC30008AC2T)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GC30008AC2T and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.