verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC300 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC300-08 FRL Unit (GC30008AC2WT)

The AirTAC GC300-08 FRL Unit (GC30008AC2WT) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/4" ports, a 5 µm element, a automatic drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/4"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainAutomatic drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$121.11 $128.61Save 5% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GC300-08 drain, gauge and thread option on one page All GC300-08 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GC300-08 FRL Unit (GC30008AC2WT)

The GC300-08 is an AirTAC GC-series three-unit F.R.L. combination: a filter, a regulator and a lubricator delivered as one set for a 1/4 in NPT port line. This configuration carries the optional 5 um filter element (tighter than the 40 um standard), an automatic drain on the filter bowl, a standard regulator with a 0.15-0.9 MPa (20-130 psi) adjustment range, and a round pressure gauge reading in psi. Maximum inlet pressure is 1.0 MPa (145 psi), the polycarbonate bowls suit the -5 to 70 C non-freezing range, and a mounting bracket is included.

This is a genuine AirTAC part. The GC line is published in sizes 200, 300, 400 and 600 with ports from 1/8 in to 1 in, in three thread types (NPT on this code), with drain type, filter grade, gauge style and scale, and a reverse/check valve as orderable options. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet and check sizing for your application before ordering. Order code GC30008AC2WT has NPT ports (the T in the code) for North American pipe fittings.

AirTAC GC300-08 FRL Unit (GC30008AC2WT) Technical Specifications

ModelAirTAC GC300-08 FRL Unit (GC30008AC2WT)
SeriesGC300 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/4" (NPT thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeAutomatic drain
Bowl materialPC
Pressure gaugeFitted — round, psi scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC300-08 FRL Unit (GC30008AC2WT)

GC300G-series F.R.L. combination, 300 body — sets the port range.
08Port size PT1/4". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
ADrain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-08 filter, GR300-08 regulator and GL300-08 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC300 · PT1/4" · 5 µm
One size downGC200
One size upGC400
Two-unit equivalentGFC300-08
Build orderFilter → regulator → lubricator

Where the AirTAC GC300-08 FRL Unit (GC30008AC2WT) Is Used

factory

Automotive paint shop air drops

At a spray-booth drop, the set filters water and sludge down to 5 um ahead of the guns, holds a set regulator pressure for consistent atomising, and carries oil mist to the air tools used between coats.

precision_manufacturing

CNC machining cell point-of-use

Mounted at the wall drop feeding a machining centre, the combination cleans the shop air to 5 um, sets the pressure the machine's air circuit expects, and lubricates the actuated tool-clamp and chip-door cylinders.

conveyor_belt

Packaging line cartoner feed

On a cartoning conveyor, the unit conditions the supply to the pick-and-place cylinders: filtered air for the valves, regulated pressure for gentle box handling, and oil mist to keep the cylinders sealing well over long shifts.

Is the AirTAC GC300-08 FRL Unit (GC30008AC2WT) the Right Station?

Size and port come first: the 300 size with its 1/4 in NPT port sits mid-range in the GC line (200/300/400/600), and the right step depends on the air demand of the circuit downstream - we can check the published flow curves against your consumption. Drain: this unit has an automatic drain, which empties the filter bowl without manual intervention; manual and differential-pressure drains are the alternatives. Filter grade: the fitted 5 um element (code W) protects finer downstream equipment than the 40 um standard. The round gauge reads in psi; an embedded square gauge and MPa or bar scales are the other options. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Because flow is published as curves, not a single rating, confirm sizing with us before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/4" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-08 regulator with a GF300-08 filter on that branch.

AirTAC GC300-08 FRL Unit (GC30008AC2WT) FAQ

AirTAC publishes flow for the GC series as curves rather than a single rated figure, so we do not quote a number. Tell us your line pressure and air consumption and we will confirm the datasheet curve and check the 300 size with its 1/4 in port against your application before you order.

The W code on this unit specifies the optional 5 um grade, which catches finer particles and sludge than the 40 um standard element - useful ahead of precision valves, cylinders or instruments. If your circuit does not need fine filtration, the 40 um standard is the lower-restriction choice; we can confirm both grades on the datasheet.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GC300-08 FRL Unit (GC30008AC2WT)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GC30008AC2WT and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.