AirTAC GC300 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC300-08 FRL Unit (GC30008ALC1T)

The AirTAC GC300-08 FRL Unit (GC30008ALC1T) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/4" ports, a 40 µm element, a automatic drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/4"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainAutomatic drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$121.11 $128.61Save 5% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GC300-08 drain, gauge and thread option on one page All GC300-08 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GC300-08 FRL Unit (GC30008ALC1T)

GC is AirTAC's three-unit F.R.L. combination - separate filter, regulator and lubricator - giving filtered, regulated, oil-mist lubricated compressed air from one assembly. This GC30008ALC1T is the 300 size with NPT1/4 ports, an automatic drain on the filter bowl, the standard 40 um element, and the low-pressure (L) regulator type that adjusts up to 0.4 MPa, where the standard type spans 0.15 to 0.9 MPa (20-130 psi) with automatic drain. A round external pressure gauge with an MPa scale is fitted. Maximum inlet pressure is 1.0 MPa (145 psi), the 300 filter bowl is PC (polycarbonate), and the temperature range is -5 to 70 C, non-freezing.

This is a genuine AirTAC part. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Flow is published as curves rather than a single rating, so we confirm flow and datasheet figures on request.

AirTAC GC300-08 FRL Unit (GC30008ALC1T) Technical Specifications

ModelAirTAC GC300-08 FRL Unit (GC30008ALC1T)
SeriesGC300 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/4" (NPT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeAutomatic drain
Bowl materialPC
Pressure gaugeFitted — round, MPa scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC300-08 FRL Unit (GC30008ALC1T)

GC300G-series F.R.L. combination, 300 body — sets the port range.
08Port size PT1/4". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
ADrain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-08 filter, GR300-08 regulator and GL300-08 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC300 · PT1/4" · 40 µm
One size downGC200
One size upGC400
Two-unit equivalentGFC300-08
Build orderFilter → regulator → lubricator

Where the AirTAC GC300-08 FRL Unit (GC30008ALC1T) Is Used

tune

Extrusion line cooling blow-off

Regulates air down to gentle pressures for air knives and nozzles cooling plastic profile as it leaves the extruder, with the automatic drain keeping bowl condensate off the line.

science

Laboratory test rig actuators

Conditions the supply to pneumatically actuated fixtures on a lab or QC test bench where setpoints sit in the low-pressure band and a clear MPa gauge readout is wanted.

factory

Food tray-sealing machine

Feeds sealing heads and product-handling cylinders on a tray-sealing line that runs at reduced pressure, with lubricated air protecting the sealing cylinders and valves.

Is the AirTAC GC300-08 FRL Unit (GC30008ALC1T) the Right Station?

Pick the L-coded unit when the machine needs regulated pressure well below the normal range: this low-pressure type adjusts up to 0.4 MPa, while the standard type reaches 0.9 MPa (20-130 psi with automatic drain). The 300 size with NPT1/4 ports is the mid step; resize to 200 or 400/600 to match the line. Drain here is automatic, so the bowl clears condensate unattended; manual and differential-pressure types are alternatives, and the standard 40 um element suits general duty with the 5 um W option for finer filtration. The round external gauge reads in MPa; square embedded gauges and bar or psi scales exist. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Flow appears only as curves, so ask us to confirm sizing before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT1/4" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-08 regulator with a GF300-08 filter on that branch.

AirTAC GC300-08 FRL Unit (GC30008ALC1T) FAQ

We do not quote a rated flow because AirTAC publishes G-series performance as curves, not as a single figure. Send your line pressure and air demand and we will confirm the flow and sizing from the datasheet on request.

L selects the low-pressure regulator type: adjustment goes up to 0.4 MPa instead of the standard type's 0.15 to 0.9 MPa (20-130 psi) range. Inlet pressure is still up to 1.0 MPa, so the unit fits a normal plant air main and steps the pressure down.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GC300-08 FRL Unit (GC30008ALC1T)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GC30008ALC1T and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.