AirTAC GC300 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC300-08 FRL Unit (GC30008C3TK)

The AirTAC GC300-08 FRL Unit (GC30008C3TK) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/4" ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/4"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$122.34 $129.84Save 5% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GC300-08 drain, gauge and thread option on one page All GC300-08 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GC300-08 FRL Unit (GC30008C3TK)

GC30008C3TK is an AirTAC G-series three-unit F.R.L. combination: separate filter, regulator and lubricator units supplied as one set for compressed air. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. The K suffix means a reverse (check) valve is fitted, exactly as listed in the AirTAC catalogue for this code.

This is a genuine AirTAC part. The G-series F.R.L. sets are made in 200, 300, 400 and 600 sizes with ports from 1/8 in to 1 in, a choice of differential-pressure, automatic or manual drains, 40 um standard or 5 um (W) fine filtration, MPa, psi or bar gauge scales, and G(BSPP) or NPT thread options. Maximum working pressure is 1.0 MPa (145 psi) and operating temperature is -5 to 70 C, non-freezing. Flow is published as curves, so ask us and we will confirm the datasheet figures for this exact model on request.

AirTAC GC300-08 FRL Unit (GC30008C3TK) Technical Specifications

ModelAirTAC GC300-08 FRL Unit (GC30008C3TK)
SeriesGC300 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/4" (NPT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — round, bar scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC300-08 FRL Unit (GC30008C3TK)

GC300G-series F.R.L. combination, 300 body — sets the port range.
08Port size PT1/4". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
3Gauge scale: bar. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-08 filter, GR300-08 regulator and GL300-08 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC300 · PT1/4" · 40 µm
One size downGC200
One size upGC400
Two-unit equivalentGFC300-08
Build orderFilter → regulator → lubricator

Where the AirTAC GC300-08 FRL Unit (GC30008C3TK) Is Used

engineering

Assembly-press air supply

Feeds the clamping and ejection cylinders of a small pneumatic assembly press, with the check valve specified as part of the press circuit.

build

Modular pneumatic panel build

Serves as the conditioning set on a machine builder's air panel, where the K option is written into the builder's standard BOM.

local_shipping

Dock equipment actuator supply

Conditions the air for leveler and restraint actuators at a loading dock, with the regulator set to the equipment maker's stated pressure.

Is the AirTAC GC300-08 FRL Unit (GC30008C3TK) the Right Station?

This code is the check-valve version of the GC30008C3: same 300 size, 1/4 in NPT port, 40 um element, differential-pressure drain and bar-scaled round gauge, with the K option adding a reverse (check) valve. Choose the non-K code if your circuit handles backflow elsewhere; keep the K code where the check valve is part of your specified circuit design. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/4" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-08 regulator with a GF300-08 filter on that branch.

AirTAC GC300-08 FRL Unit (GC30008C3TK) FAQ

AirTAC publishes flow for the G-series as curves rather than a single rated figure, so we do not quote a number on this page. Share your operating pressure and demand and we will confirm the datasheet curve for this 300-size, 1/4 in set on request.

Only the trailing K: this model has a reverse (check) valve fitted, while the plain C3 code does not. Size (300), port (NPT1/4), filter grade (40 um), drain (differential-pressure) and gauge (round, bar) are identical, so the choice comes down to whether the check valve is called for in your circuit.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GC300-08 FRL Unit (GC30008C3TK)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GC30008C3TK and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.