The AirTAC GC300-08 FRL Unit (GC30008F1WT) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/4" ports, a 5 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
GC30008F1WT is a GC-series three-unit F.R.L. combination for 1/4 inch G (BSPP) ports in size 300, and the W suffix means the filter stage carries the finer 5 um element instead of the 40 um standard. Drain is differential-pressure, the regulator adjusts from 0.15 to 0.9 MPa (20-130 psi) with a square MPa gauge included, and the lubricator meters oil mist into the downstream air. Maximum inlet pressure is 1.0 MPa (145 psi), temperature range is -5 to 70 C, and the bowls are PC (polycarbonate) at this size.
This is a genuine AirTAC part. The G series runs from size 200 to 600 with ports from 1/8 to 1 inch, and drain type, filter grade, gauge scale, reverse/check valve and G or NPT threads are all selectable options. AirTAC publishes flow as curves rather than a single rating, so we confirm the datasheet figures for your application on request.
| Model | AirTAC GC300-08 FRL Unit (GC30008F1WT) |
|---|---|
| Series | GC300 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | PT1/4" (NPT thread) |
| Filtering grade | 5 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — square, MPa scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC300 | G-series F.R.L. combination, 300 body — sets the port range. |
|---|---|
| 08 | Port size PT1/4". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 1 | Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar. |
| W | Filtering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-08 filter, GR300-08 regulator and GL300-08 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC300 · PT1/4" · 5 µm |
|---|---|
| One size down | GC200 |
| One size up | GC400 |
| Two-unit equivalent | GFC300-08 |
| Build order | Filter → regulator → lubricator |
Supplies the finer-filtered, regulated air feeding pressure gauges, transducers and reference instruments on a pneumatic test bench, with lubrication kept downstream of the instrumentation.
Conditions the air driving shut-off screwdrivers on an electronics or light-assembly line, where a cleaner 5 um supply protects the tool's internal valve parts.
Prepares the supply going into compact valve manifolds and small-bore actuators where finer filtration ahead of the regulator helps guard the close-tolerance internals.
Pick the W code when the circuit needs finer filtration than the 40 um default: 5 um suits instrument-quality air on the same size 300 body. The port step (1/4 inch G here, sizes 200 to 600 available) should match your air demand. Drain is differential-pressure as decoded (automatic or manual are options), and gauge scale plus thread (NPT on this code) complete the choices.
Because flow is published as performance curves and not a single rated number, send your application conditions and we will confirm sizing against the datasheet before you order.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-08 regulator with a GF300-08 filter on that branch.
AirTAC publishes flow for the GC series as performance curves rather than a single rated figure, so we do not quote one number. Share your line pressure and demand and we will confirm the sizing from the datasheet on request.
Stay with 40 um for general cylinder and tool air; choose 5 um (this W code) when the downstream equipment needs finer filtration, such as instrumentation or precision air tools. It is the same GC300 body with a different element, and we can confirm details on request.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.