The AirTAC GC300-08 FRL Unit (GC30008LC1T) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/4" ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
This GC30008LC1T is AirTAC's three-piece F.R.L. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. The filter carries the 40 um standard element with differential-pressure drainage, and the gauge is the round external type scaled in MPa. The 300-size filter and lubricator bowls are polycarbonate. The medium is compressed air; maximum working pressure is 1.0 MPa (145 psi) and the working temperature is -5 to 70 C, non-freezing.
You are ordering a genuine AirTAC part. The GC series is also available in sizes 200, 300, 400 and 600 with ports from 1/8-inch to 1-inch, G (BSPP) or NPT threads, manual or automatic drains, 40 um or 5 um elements and square embedded gauges as catalogue alternatives. Because the exact adjustment range of the low-pressure type depends on the variant, and flow is published as curves rather than a single rating, we confirm both from the datasheet on request.
| Model | AirTAC GC300-08 FRL Unit (GC30008LC1T) |
|---|---|
| Series | GC300 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | PT1/4" (NPT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Low-pressure type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — round, MPa scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC300 | G-series F.R.L. combination, 300 body — sets the port range. |
|---|---|
| 08 | Port size PT1/4". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| L | Low-pressure type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| C | Gauge shape: Round. C is round, F is square. |
| 1 | Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-08 filter, GR300-08 regulator and GL300-08 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC300 · PT1/4" · 40 µm |
|---|---|
| One size down | GC200 |
| One size up | GC400 |
| Two-unit equivalent | GFC300-08 |
| Build order | Filter → regulator → lubricator |
Light, fast pick-and-place actuators that run at modest circuit pressures take filtered and lubricated air from this low-pressure F.R.L. set, with the MPa gauge showing the gentle settings.
Panel-mounted pilot and sensing circuits that must not see full line pressure are fed through this set, with the regulator trimmed to the low setting the control valves were designed around.
Bottling machine lifters and gating cylinders running at reduced pressures draw conditioned NPT1/4 air from this unit, combining fine-drained filtration with light lubrication of the actuators.
Size 300 with NPT1/4 ports suits lines built on 1/4-inch pipework; step to sizes 200, 400 or 600 where the port or air demand differs. The L code selects the low-pressure regulator type - confirm the exact setting range with us, since the published ranges above apply to the standard type. Drainage here is differential-pressure, with manual and automatic drains orderable, and filtration is the standard 40 um element (5 um with the W code). The C1 suffix gives the round external gauge with an MPa scale. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. G (BSPP) and NPT are catalogue options to order.
Flow for the GC series is published as curves, not a single rated figure, so ask us to verify the sizing against your low-pressure application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-08 regulator with a GF300-08 filter on that branch.
AirTAC publishes flow for the GC series as curves rather than a single rated figure, so we do not quote a number here. Give us your circuit pressure and air consumption and we will confirm the sizing from the datasheet on request.
L marks the low-pressure regulator type, intended for circuits set below the standard type's typical working range. The exact adjustment range varies, so confirm it with us before ordering; the rest of the decode is the size 300, NPT1/4, 40 um, differential-pressure-drain F.R.L. with a round MPa gauge.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.