AirTAC GC300 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC300-08 FRL Unit (GC30008MLNT)

The AirTAC GC300-08 FRL Unit (GC30008MLNT) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/4" ports, a 40 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/4"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade40 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeNot fitted
  • ThreadNPT
$100.01 $107.51Save 6% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GC300-08 drain, gauge and thread option on one page All GC300-08 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GC300-08 FRL Unit (GC30008MLNT)

GC30008MLNT is an AirTAC GC three-unit air-treatment combination: a separate air filter, pressure regulator and lubricator piped together. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. The filter bowl has a manual drain and the standard 40 um element; the regulator is the low-pressure type (code L) with a 0.05-0.9 MPa (7-130 psi) setting range for this manual-drain configuration; code N means the set is supplied without a gauge. Maximum working pressure is 1.0 MPa (145 psi), temperature range is -5 to 70 C (non-freezing), and the 300-size filter and lubricator bowls are PC (polycarbonate).

This is a genuine AirTAC part. The GC series spans 200, 300, 400 and 600 sizes with ports from 1/8 in to 1 in, and drain, filter grade, gauge, thread and valve options are order choices. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet figures for your application.

AirTAC GC300-08 FRL Unit (GC30008MLNT) Technical Specifications

ModelAirTAC GC300-08 FRL Unit (GC30008MLNT)
SeriesGC300 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/4" (NPT thread)
Filtering grade40 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeNot fitted
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC300-08 FRL Unit (GC30008MLNT)

GC300G-series F.R.L. combination, 300 body — sets the port range.
08Port size PT1/4". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
NNo pressure gauge (N).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-08 filter, GR300-08 regulator and GL300-08 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC300 · PT1/4" · 40 µm
One size downGC200
One size upGC400
Two-unit equivalentGFC300-08
Build orderFilter → regulator → lubricator

Where the AirTAC GC300-08 FRL Unit (GC30008MLNT) Is Used

precision_manufacturing

CNC machine pneumatics

General air supply to a CNC machining center's chip conveyors, tool-change cylinders and air blast: filtered, regulated and lubricated air from a panel where the machine's own pressure display makes a separate gauge redundant.

local_shipping

Trailer dock equipment

Feeding dock levellers and shelter cushions on a loading bay: the 40 um element handles typical plant air, the regulator sets actuation pressure, and the manual drain is emptied during scheduled dock checks.

handyman

Maintenance shop manifold

A prepared drop at a maintenance shop bench: one filter-regulator-lubricator set feeding impact tools and test rigs, with pressure read off the shop's existing gauge rather than a dedicated instrument on the set.

Is the AirTAC GC300-08 FRL Unit (GC30008MLNT) the Right Station?

Choose the 300 size with 1/4 in NPT ports for compact machine supply lines, or step to 200, 400 or 600 as port and flow demand changes. Drain is manual on this set (widest 0.05-0.9 MPa setting range); automatic and differential-pressure drains are available. The standard 40 um element suits general machine air; specify the W code for 5 um where equipment needs finer air. This N code has no gauge - order the gauge versions (square, or external round, in MPa, psi or bar scales) if operators need to read the setpoint. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Flow is published as curves, not a single rating - ask us to confirm sizing before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/4" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-08 regulator with a GF300-08 filter on that branch.

AirTAC GC300-08 FRL Unit (GC30008MLNT) FAQ

AirTAC publishes G-series flow as curves, not as a single rated figure, so we do not state a rated flow number here. Share your working pressure and consumption and we will confirm the datasheet flow curve for this 300-size set on request.

The 40 um standard grade suits general machine air - cylinders, valves and shop tools. If you feed spray equipment, precision valves or instrumentation, order the W version (GC30008MLNW) with the 5 um element instead. Both share the same 300-size, 1/4 in NPT, manual-drain layout.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GC300-08 FRL Unit (GC30008MLNT)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GC30008MLNT and will confirm price, availability and lead time — usually within 7 hours.