AirTAC GC300 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC300-08 FRL Unit (GC30008NWTK)

The AirTAC GC300-08 FRL Unit (GC30008NWTK) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/4" ports, a 5 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/4"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeNot fitted
  • ThreadNPT
$114.94 $122.44Save 6% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GC300-08 drain, gauge and thread option on one page All GC300-08 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GC300-08 FRL Unit (GC30008NWTK)

GC30008NWTK is a genuine AirTAC G-series three-unit F.R.L. combination: a separate air filter, a pressure regulator and an oil-mist lubricator, sized 300 with a 1/4 inch NPT port. The W suffix specifies the finer 5 um filter element instead of the standard 40 um grade, and the K suffix means a reverse (check) valve is fitted. The filter drains by differential pressure, the regulator adjusts from 0.15 to 0.9 MPa (20-130 psi), the max working pressure is 1.0 MPa (145 psi), no gauge is fitted, and the polycarbonate bowls suit -5 to 70 C (non-freezing) compressed air.

This is a genuine AirTAC part from the G series, which spans sizes 200, 300, 400 and 600 with three thread types (NPT on this code), gauge scales in MPa, psi or bar, and manual or automatic drain variants. Published flow data appears as curves rather than a single rated figure, so we confirm sizing and full datasheet figures on request before you order.

AirTAC GC300-08 FRL Unit (GC30008NWTK) Technical Specifications

ModelAirTAC GC300-08 FRL Unit (GC30008NWTK)
SeriesGC300 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/4" (NPT thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeNot fitted
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC300-08 FRL Unit (GC30008NWTK)

GC300G-series F.R.L. combination, 300 body — sets the port range.
08Port size PT1/4". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
NNo pressure gauge (N).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-08 filter, GR300-08 regulator and GL300-08 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC300 · PT1/4" · 5 µm
One size downGC200
One size upGC400
Two-unit equivalentGFC300-08
Build orderFilter → regulator → lubricator

Where the AirTAC GC300-08 FRL Unit (GC30008NWTK) Is Used

engineering

Robotics end-of-arm air prep

For a robot cell's gripper and clamp circuit, this set delivers finely filtered, regulated, oiled air with the built-in check valve, in one compact supply assembly.

local_shipping

Trailer brake-test and door rigs

On workshop rigs that cycle trailer doors and test equipment, the set conditions the shop air to 5 um cleanliness and keeps the regulator and lubricator doing their job shift after shift.

tune

Textile machine air jets and cylinders

On textile machinery running air jets and small cylinders, the combination supplies finely filtered, regulated and lubricated air, with the check valve fitted as the code specifies.

Is the AirTAC GC300-08 FRL Unit (GC30008NWTK) the Right Station?

GC30008NWTK combines the two main options in one code: the W suffix gives 5 um filtration instead of the 40 um standard, and K adds the built-in reverse (check) valve. Everything else matches the base GC30008N - size 300, 1/4 inch NPT port, differential-pressure drain, regulator range 0.15-0.9 MPa (20-130 psi), no gauge. Step to size 400 (1/2 inch port) for higher flow demand.

This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. a bracket is included and a gauge with MPa, psi or bar scale can be ordered. Because flow is published as curves rather than a single rating, ask us to confirm sizing against your air consumption before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/4" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-08 regulator with a GF300-08 filter on that branch.

AirTAC GC300-08 FRL Unit (GC30008NWTK) FAQ

AirTAC publishes flow for the GC series as performance curves, not as a single rated figure, so we do not quote one number. Send us your line pressure and air consumption and we will confirm the sizing and full datasheet figures on request before you order.

W specifies the finer 5 um filter element instead of the 40 um standard, and K means a reverse (check) valve is fitted. Both are the only differences from the plain GC30008N - the size, port, drain and regulator function are otherwise the same.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GC300-08 FRL Unit (GC30008NWTK)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GC30008NWTK and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.