The AirTAC GC400-15 FRL Unit (GC40015AC2T) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/2" ports, a 40 µm element, a automatic drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/2"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainAutomatic drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$168.92 $176.42Save 4% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GC400-15 drain, gauge and thread option on one page All GC400-15 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GC400-15 FRL Unit (GC40015AC2T)

The GC series is AirTAC's three-piece F.R.L. combination: a separate air filter, pressure regulator and lubricator built up as one unit, so filtration, regulation and oil-mist lubrication are all handled in a single installation. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. The polycarbonate bowls suit the -5 to 70 C (non-freezing) operating range, and the maximum inlet pressure is 1.0 MPa (145 psi).

This is a genuine AirTAC part. The GC family is published in 200, 300, 400 and 600 sizes with ports from 1/8 to 1 inch, and options that include a 5 um filter element (code W), manual or differential-pressure drains, G or NPT threads, and gauge scales in MPa, psi or bar. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet figures for your application. Order code GC40015AC2T has NPT ports (the T in the code) for North American pipe fittings.

AirTAC GC400-15 FRL Unit (GC40015AC2T) Technical Specifications

ModelAirTAC GC400-15 FRL Unit (GC40015AC2T)
SeriesGC400 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/2" (NPT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeAutomatic drain
Bowl materialPC
Pressure gaugeFitted — round, psi scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC400-15 FRL Unit (GC40015AC2T)

GC400G-series F.R.L. combination, 400 body — sets the port range.
15Port size PT1/2". This body offers 10 = PT3/8", 15 = PT1/2".
ADrain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-15 filter, GR400-15 regulator and GL400-15 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC400 · PT1/2" · 40 µm
One size downGC300
One size upGC600
Two-unit equivalentGFC400-15
Build orderFilter → regulator → lubricator

Where the AirTAC GC400-15 FRL Unit (GC40015AC2T) Is Used

precision_manufacturing

CNC machining cells

Machine shops running pneumatic clamps, tool-change cylinders and air-blast chip clearing on CNC centres can feed the whole cell from one GC40015AC2T: the filter strips water and swarf-carrying particulate, the regulator holds a steady set pressure, and the lubricator mists oil to the air tools downstream.

factory

Automotive assembly lines

Assembly stations where impact wrenches, ratchets and air cylinders work shift after shift benefit from a single point of treatment. This unit cleans the supply, locks the line pressure against upstream swings, and carries oil mist to the tools, all from one NPT1/2 drop leg.

conveyor_belt

Packaging and bottling lines

High-cycle packaging machinery with pick-and-place cylinders, grippers and diverters depends on clean, dry, correctly pressured air. A GC40015AC2T at the line inlet removes condensate automatically via its drain, holds the regulator setpoint, and lubricates the actuators so the line keeps cycling.

Is the AirTAC GC400-15 FRL Unit (GC40015AC2T) the Right Station?

Size and port are the first choice: the 400 size with its NPT1/2 port sits in the middle of the 200-600 range, so step up or down according to the air your line actually uses. Beyond that, the real decodable choices are the drain (automatic here; manual and differential-pressure are available), the filter grade (40 um standard, 5 um with code W), the gauge and its scale (this unit carries a round psi gauge), and the thread (NPT on this code). Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-15 regulator with a GF400-15 filter on that branch.

AirTAC GC400-15 FRL Unit (GC40015AC2T) FAQ

AirTAC publishes flow for the GC series as performance curves rather than a single rated figure, so we do not quote a rated flow, Cv or SCFM number. Tell us your application and required flow, and we will confirm the figures from the datasheet for this 400-size, NPT1/2 unit before you order.

The A in GC40015AC2T decodes to an automatic drain on the filter bowl, which handles condensate without anyone having to open the drain by hand. Manual and differential-pressure drains are also available in the family. Note that the regulation range is quoted by drain type: with the automatic drain fitted, the standard regulator adjusts from 0.15 to 0.9 MPa (20-130 psi).

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GC400-15 FRL Unit (GC40015AC2T)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GC40015AC2T and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.