The AirTAC GC400-15 FRL Unit (GC40015AF1WTK) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/2" ports, a 5 µm element, a automatic drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The AirTAC GC series is a three-unit F.R.L. combination: a separate air filter, a pressure regulator and a lubricator supplied as one set. This GC40015AF1WTK is size 400 with 1/2 in NPT ports, an automatic drain on the filter bowl, a 5 um filter element, a square gauge scaled in MPa and, per the trailing K, a reverse (check) valve fitted. In service it filters water and particulate from the air, holds a steady downstream pressure adjustable from 0.15 to 0.9 MPa (20 to 130 psi), and meters oil mist to lubricate downstream equipment.
This is a genuine AirTAC part. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Size 400 bowls are polycarbonate; maximum working pressure is 1.0 MPa (145 psi) and the temperature range is -5 to 70 C (non-freezing). Flow is published as curves rather than a single rating - ask us and we will confirm the datasheet figures for your application.
| Model | AirTAC GC400-15 FRL Unit (GC40015AF1WTK) |
|---|---|
| Series | GC400 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | PT1/2" (NPT thread) |
| Filtering grade | 5 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Automatic drain |
| Bowl material | PC |
| Pressure gauge | Fitted — square, MPa scale |
| Reflux valve | Fitted (reverse flow permitted) |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC400 | G-series F.R.L. combination, 400 body — sets the port range. |
|---|---|
| 15 | Port size PT1/2". This body offers 10 = PT3/8", 15 = PT1/2". |
| A | Drain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 1 | Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar. |
| W | Filtering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| K | Reverse-flow (reflux) valve fitted. |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-15 filter, GR400-15 regulator and GL400-15 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC400 · PT1/2" · 5 µm |
|---|---|
| One size down | GC300 |
| One size up | GC600 |
| Two-unit equivalent | GFC400-15 |
| Build order | Filter → regulator → lubricator |
Feeds the capper heads and indexing cylinders of a bottling line, where the automatic drain handles condensate from a wet plant air main through the shift.
Conditions the air feeding loom jet valves and take-up cylinders, with the 5 um element suiting the sensitive solenoid valves on modern looms.
Supplies counterbalance and holding cylinders on a mechanical power press, with the fitted reverse (check) valve per the K suffix as part of the circuit design.
This is the check-valve version of the GC40015AF1W: same size 400 body, 1/2 in NPT ports, automatic drain and 5 um element, with the reverse valve added per the K suffix. If you do not need the valve, the non-K part is the equivalent. Down one size is the 300 series at 3/8 in and down another the 200 at 1/4 in; up is the 600 for larger lines. Gauge scale here is MPa (psi and bar versions exist), G and NPT threads are orderable, and a mounting bracket is available. Flow is published as curves, not one rated figure, so send us your application details and we will confirm sizing before you order.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-15 regulator with a GF400-15 filter on that branch.
AirTAC publishes flow for this series as curves rather than a single rated figure, so there is no one number to quote. Share your line pressure and consumption and we will confirm the datasheet flow data for this size 400, 1/2 in set against your application before you order.
The trailing K decodes as a reverse (check) valve fitted on this unit. Functionally it is the same three-unit filter, regulator and lubricator set as the GC40015AF1W - same 1/2 in NPT ports, automatic drain, 5 um element and MPa gauge - with the valve added.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.