The AirTAC GC400-15 FRL Unit (GC40015AF3WT) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/2" ports, a 5 µm element, a automatic drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
GC40015AF3WT is an AirTAC GC-series three-unit F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one set. This 400-size configuration carries a NPT1/2 port, automatic drain on the filter bowl, 5 um filtration and a square pressure gauge scaled in bar. In service it strips water and particulate from the compressed air, holds the downstream pressure you set on the regulator, and meters a fine oil mist into the line for downstream air tools and cylinders.
This is a genuine AirTAC part for compressed air, rated for a maximum working pressure of 1.0 MPa (145 psi) and a media temperature of -5 to 70 C (non-freezing). The 400 size uses polycarbonate bowls, and with automatic drain the regulator adjusts from 0.15 to 0.9 MPa. AirTAC publishes flow as performance curves rather than a single rated figure, so we confirm sizing and full datasheet figures on request. This version has NPT ports (the T in the order code) for North American pipe fittings.
| Model | AirTAC GC400-15 FRL Unit (GC40015AF3WT) |
|---|---|
| Series | GC400 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | PT1/2" (NPT thread) |
| Filtering grade | 5 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Automatic drain |
| Bowl material | PC |
| Pressure gauge | Fitted — square, bar scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC400 | G-series F.R.L. combination, 400 body — sets the port range. |
|---|---|
| 15 | Port size PT1/2". This body offers 10 = PT3/8", 15 = PT1/2". |
| A | Drain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 3 | Gauge scale: bar. 1 is MPa, 2 is psi, 3 is bar. |
| W | Filtering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-15 filter, GR400-15 regulator and GL400-15 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC400 · PT1/2" · 5 µm |
|---|---|
| One size down | GC300 |
| One size up | GC600 |
| Two-unit equivalent | GFC400-15 |
| Build order | Filter → regulator → lubricator |
Filters, regulates and lubricates the air feeding pneumatic cylinders that start, stop and index conveyors on a beverage bottling line, with automatic drain keeping the bowl clear between shifts.
A branch supply point for impact wrenches, air ratchets and blow guns at a repair-shop bench, delivering clean, pressure-set, oil-misted air to hand tools all day.
Conditions the air feeding vacuum generators and gripper cylinders on a pick-and-place cell, where the 5 um element protects fine valve spools from water and particulate carryover.
The GC range steps through 200, 300, 400 and 600 sizes, each with its own port and flow band, so match the 400 size and NPT1/2 port to the air demand of the machine it feeds. Drain choice is decodable: automatic (this code), manual, or the differential-pressure default; automatic suits unmanned cells where the bowl is hard to reach. Filter grade is 40 um as standard, or 5 um as here (W) where finer pre-filtration matters. The gauge on this unit is the square type scaled in bar; This order code has NPT ports (the T in the code); the PT and G versions are separate order codes.
Flow is published as curves, not a single rated number, so send us your application demand and we will confirm sizing against the datasheet before you order.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-15 regulator with a GF400-15 filter on that branch.
AirTAC publishes flow for the GC series as performance curves rather than a single rated figure, so quoting one number would be misleading. Tell us your downstream demand and working pressure and we will confirm the correct size from the datasheet before you order.
The GC series offers differential-pressure drain as the default, plus manual (A not coded, M for manual) and automatic (A) options. The automatic drain on this model ejects condensate on its own, which suits installations the maintenance team does not visit daily. Note that with automatic drain the regulator adjusts from 0.15 to 0.9 MPa.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.