The AirTAC GC400-15 FRL Unit (GC40015ALC1WT) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/2" ports, a 5 µm element, a automatic drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
GC40015ALC1WT is an AirTAC GC-series three-unit F.R.L. combination: separate filter, regulator and lubricator piped as one set. The L specifies the low-pressure regulator type adjusting up to 0.4 MPa, C1 fits an external round gauge scaled in MPa, and the W suffix upgrades the filter element to 5 um. This 400-size unit carries a NPT1/2 port and an automatic-drain filter bowl.
This is a genuine AirTAC part for compressed air, rated to 1.0 MPa (145 psi) maximum working pressure and -5 to 70 C (non-freezing), with polycarbonate bowls at the 400 size. The standard GC400 filter grade is 40 um and the standard regulator with automatic drain adjusts 0.15 to 0.9 MPa; this code departs from both. Flow is published as curves, not a single rating, so we confirm sizing and datasheet figures on request. This version has NPT ports (the T in the order code) for North American pipe fittings.
| Model | AirTAC GC400-15 FRL Unit (GC40015ALC1WT) |
|---|---|
| Series | GC400 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | PT1/2" (NPT thread) |
| Filtering grade | 5 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Low-pressure type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Automatic drain |
| Bowl material | PC |
| Pressure gauge | Fitted — round, MPa scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC400 | G-series F.R.L. combination, 400 body — sets the port range. |
|---|---|
| 15 | Port size PT1/2". This body offers 10 = PT3/8", 15 = PT1/2". |
| A | Drain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| L | Low-pressure type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| C | Gauge shape: Round. C is round, F is square. |
| 1 | Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar. |
| W | Filtering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-15 filter, GR400-15 regulator and GL400-15 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC400 · PT1/2" · 5 µm |
|---|---|
| One size down | GC300 |
| One size up | GC600 |
| Two-unit equivalent | GFC400-15 |
| Build order | Filter → regulator → lubricator |
Delivers finely filtered, low-pressure, oil-misted air to pneumatic actuators inside an analytical instrument enclosure, where the 5 um element protects sensitive pilot components.
Conditions the low-pressure air feeding loom clamp and doffing cylinders in a weaving shed, with 5 um filtration limiting particulate that would mark yarn guides.
Regulates air to the mold-close and ejector cylinders of a foam molding press running at gentle setpoints, with automatic drainage suiting a hot, lightly attended corner of the plant.
This code combines two upgrades over the GC400 baseline: the low-pressure (L) regulator type with adjustment up to 0.4 MPa, and the W filter grade at 5 um instead of the standard 40 um. Choose it when the process runs at low setpoints and the downstream valves or actuators need finer filtration. Drain is automatic; manual and differential-pressure are the other decodable options. Gauge is the round external type in MPa; This order code has NPT ports (the T in the code); the PT and G versions are separate order codes.
Since rated flow appears only as curves, ask us to check this 400-size set against your demand before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-15 regulator with a GF400-15 filter on that branch.
AirTAC publishes flow for the GC series as curves rather than a single rated figure, so there is no one number to quote. Provide your machine's air demand and working pressure and we will confirm sizing and supply the datasheet on request.
The GC series filters at 40 um as standard and offers 5 um via the W suffix, as fitted here. Choose 5 um when downstream directional valves, pilot-operated components or precision actuators need finer protection from particulate; note it sits on the same automatic-drain filter bowl of this low-pressure three-unit set.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.