The AirTAC GC400-15 FRL Unit (GC40015ALF1T) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/2" ports, a 40 µm element, a automatic drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
GC40015ALF1T is the 400-size, three-unit F.R.L. combination from AirTAC's G series: a separate air filter, pressure regulator and lubricator working together as one set to clean, regulate and oil-mist-lubricate compressed air. This configuration is built for 1/2 in. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Maximum working pressure is 1.0 MPa (145 psi) and the operating temperature range is -5 to 70 C, non-freezing.
This is a genuine AirTAC part. The G series F.R.L. family spans sizes 200, 300, 400 and 600, with a choice of drain type, filtration grade, gauge and thread; Published flow data appears as curves rather than a single rating, so we confirm flow and datasheet figures for your application on request.
| Model | AirTAC GC400-15 FRL Unit (GC40015ALF1T) |
|---|---|
| Series | GC400 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | PT1/2" (NPT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Low-pressure type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Automatic drain |
| Bowl material | PC |
| Pressure gauge | Fitted — square, MPa scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC400 | G-series F.R.L. combination, 400 body — sets the port range. |
|---|---|
| 15 | Port size PT1/2". This body offers 10 = PT3/8", 15 = PT1/2". |
| A | Drain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| L | Low-pressure type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 1 | Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-15 filter, GR400-15 regulator and GL400-15 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC400 · PT1/2" · 40 µm |
|---|---|
| One size down | GC300 |
| One size up | GC600 |
| Two-unit equivalent | GFC400-15 |
| Build order | Filter → regulator → lubricator |
Feeds cleaned, regulated and lubricated air to the actuator and clamp circuits of a robotic weld cell, where the automatic drain keeps condensate out of the valves without operator attention.
Supplies conditioned air to the cylinders and vacuum generators on a packaging line, with the low-pressure regulator type suited to circuits that run well below full line pressure.
Installed at point-of-use drops on an assembly line so pneumatic tools and fixtures receive filtered, pressure-stabilised and lubricated air at the 1/2 in. supply size.
Start with the size and port step against the air demand of your circuit: size 400 with 1/2 in. NPT ports sits in the middle of the G series range, with 200, 300 and 600 stepping port size and flow capacity up or down. Drain type is a real choice on the filter bowl: automatic (as coded here), manual, or the differential-pressure default. The filtration grade is 40 um standard; specify W for the 5 um element where finer air is needed. The gauge here is the embedded square type with an MPa scale; psi and bar scales, an external round gauge, or no gauge are alternative codes. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes.
Flow for this family is published as curves, not as a single rated figure, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-15 regulator with a GF400-15 filter on that branch.
AirTAC publishes flow for the G series as curves rather than a single rated figure, so there is no honest single number we can quote. Tell us your line pressure, port size and demand and we will confirm the flow from the datasheet on request before you order.
The F1 suffix decodes to the embedded square gauge with an MPa scale; F2 and F3 give psi and bar scales instead, and N omits the gauge. The L suffix selects the low-pressure regulator type, intended for circuits that run below standard pressure - we confirm its exact adjustment range from the datasheet on request.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.