The AirTAC GC400-15 FRL Unit (GC40015ANT) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/2" ports, a 40 µm element, a automatic drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
GC40015ANT is a genuine AirTAC G-series three-unit F.R.L. set: a separate air filter, pressure regulator and lubricator that together condition compressed air at one station. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. no gauge is fitted as coded (N). The standard-type regulator covers a 0.15-0.9 MPa (20-130 psi) setting range with the automatic drain, inlet pressure is up to 1.0 MPa (145 psi), the medium is compressed air, and the units operate from -5 to 70 C (non-freezing). Bowls on the 400 size are polycarbonate.
This is a genuine AirTAC part. The GC combination comes in 200, 300, 400 and 600 sizes, with a choice of drain types, 40 um or 5 um elements, gauge options and three thread types (NPT on this code). AirTAC publishes flow as characteristic curves rather than a single rating, so we confirm flow and datasheet figures on request before you order.
| Model | AirTAC GC400-15 FRL Unit (GC40015ANT) |
|---|---|
| Series | GC400 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | PT1/2" (NPT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Automatic drain |
| Bowl material | PC |
| Pressure gauge | Not fitted |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC400 | G-series F.R.L. combination, 400 body — sets the port range. |
|---|---|
| 15 | Port size PT1/2". This body offers 10 = PT3/8", 15 = PT1/2". |
| A | Drain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| N | No pressure gauge (N). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-15 filter, GR400-15 regulator and GL400-15 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC400 · PT1/2" · 40 µm |
|---|---|
| One size down | GC300 |
| One size up | GC600 |
| Two-unit equivalent | GFC400-15 |
| Build order | Filter → regulator → lubricator |
The tool-change and clamping circuits of a CNC machining center draw filtered, regulated and lubricated air from this NPT1/2 set, with the automatic drain keeping moisture out of the bowl between cycles.
Cylinder-driven case packers and conveyors on a bottling line run on conditioned air from this set, so seals last longer and regulator settings stay stable across shifts.
A NPT1/2 drop feeding impact wrenches and nutrunners on an assembly line gets clean, pressure-controlled, oil-misted air from this three-unit set.
Step between the 200/300/400/600 G-series sizes to match port size and flow demand; the 400 size with its 1/2 inch port sits mid-range for general plant air. Drain choice is automatic (fitted here), manual or the differential-pressure default, so pick automatic where bowls are hard to reach or the line runs unattended. Filter grade is 40 um standard or the 5 um W option; This order code has NPT ports (the T in the code); the PT and G versions are separate order codes.
AirTAC publishes flow as curves, not a single rated figure, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-15 regulator with a GF400-15 filter on that branch.
AirTAC publishes flow as characteristic curves rather than a single rated number, so we do not quote a one-line figure. Tell us your application and we will confirm the relevant flow and datasheet figures on request before you order.
The A in the code fits an automatic drain, which expels collected condensate without operator attention. The catalogue alternatives are manual drain (M) and the differential-pressure default, so choose per accessibility and how the machine is attended.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.