AirTAC GC400 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC400-15 FRL Unit (GC40015LC1T)

The AirTAC GC400-15 FRL Unit (GC40015LC1T) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/2" ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/2"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$155.22 $162.72Save 4% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GC400-15 drain, gauge and thread option on one page All GC400-15 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GC400-15 FRL Unit (GC40015LC1T)

The AirTAC GC40015LC1T is a three-unit F.R.L. combination: a separate air filter, pressure regulator and lubricator assembled as one set. It filters water and particulate to 40 um, regulates downstream pressure with its low-pressure (L) type regulator, adds oil-mist lubrication for air tools and cylinders, and drains condensate via the differential-pressure bowl. The 400 size carries a NPT1/2 port, and the MPa round gauge is included for pressure setting.

This is a genuine AirTAC part, offered in the 200/300/400/600 size range with port options from 1/8" to 1", G(BSPP) or NPT thread variants, automatic, manual or differential-pressure drains and a 5 um filter option. Because flow is published as curves rather than a single rating, we confirm the datasheet and flow figures for your application on request.

AirTAC GC400-15 FRL Unit (GC40015LC1T) Technical Specifications

ModelAirTAC GC400-15 FRL Unit (GC40015LC1T)
SeriesGC400 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/2" (NPT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — round, MPa scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC400-15 FRL Unit (GC40015LC1T)

GC400G-series F.R.L. combination, 400 body — sets the port range.
15Port size PT1/2". This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-15 filter, GR400-15 regulator and GL400-15 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC400 · PT1/2" · 40 µm
One size downGC300
One size upGC600
Two-unit equivalentGFC400-15
Build orderFilter → regulator → lubricator

Where the AirTAC GC400-15 FRL Unit (GC40015LC1T) Is Used

factory

Automotive trim-line clamp cylinders

Supplies filtered, regulated and lubricated air to the clamp and lift cylinders that hold trim panels on a moving assembly line, with the low-pressure type regulator suited to modest working pressures.

precision_manufacturing

CNC machining-center tool-change circuits

Feeds the air cylinders that open chip doors and actuate tool clamps, keeping moisture and grit out of the valves while oil mist keeps cylinder seals running smoothly.

conveyor_belt

Case-palletiser pusher and gripper supply

Prepares the air feeding pusher plates and gripper cylinders on a palletising conveyor, so packed cases are indexed and stacked without valve contamination sticking the sequence.

Is the AirTAC GC400-15 FRL Unit (GC40015LC1T) the Right Station?

Step up or down in size (200/300/400/600) to match the port and air demand of the machine; the 400 size with a 1/2" port suits larger general-purpose circuits. Drain choices are differential-pressure (default), automatic or manual - the differential drain here discharges as pressure drops. Filter grade is 40 um as standard; the W suffix gives 5 um. The MPa round gauge is fitted; square-gauge variants and psi/bar scales are catalogue options. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes.

Flow for this series is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-15 regulator with a GF400-15 filter on that branch.

AirTAC GC400-15 FRL Unit (GC40015LC1T) FAQ

AirTAC publishes flow for the GC series as characteristic curves rather than a single rated figure, so there is no one l/min or SCFM number we can quote honestly. Send us your application details and we will confirm the flow and datasheet figures for this 400-size, 1/2"-port set on request.

The blank drain position decodes to the differential-pressure drain, the series default: condensate discharges from the bowl when the pressure differential across it builds. If you want continuous unattended draining, the A suffix gives an automatic drain and M gives a manual drain - both are catalogue options for the filter unit of this set.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GC400-15 FRL Unit (GC40015LC1T)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GC40015LC1T and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.