The AirTAC GC400-15 FRL Unit (GC40015LNT) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/2" ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/2"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeNot fitted
  • ThreadNPT
$147.69 $155.19Save 4% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GC400-15 drain, gauge and thread option on one page All GC400-15 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GC400-15 FRL Unit (GC40015LNT)

The GC40015LNT is a three-piece AirTAC G-series F.R.L. combination: a separate air filter, pressure regulator and lubricator working as one set. Size 400 with NPT1/2 (NPT thread) ports suits a 1/2 inch compressed-air main, and this version is the low-pressure type with no gauge fitted. The filter element is the standard 40 um grade, the filter bowl drains by differential pressure, and together the three units clean, regulate at a low setting and oil-mist lubricate the air going to your equipment. The filter-section bowl in size 400 is polycarbonate (PC).

This is a genuine AirTAC part. The G-series runs from size 200 to 600, with options that include automatic or manual drains, a 5 um filter element, embedded square or external round gauges, and G (BSPP) or NPT threads as catalogue choices. Maximum working pressure is 1.0 MPa (145 psi) and the operating temperature range is -5 to 70 C, non-freezing. Flow for G-series units is published as curves rather than a single rating, so we confirm figures from the datasheet on request.

AirTAC GC400-15 FRL Unit (GC40015LNT) Technical Specifications

ModelAirTAC GC400-15 FRL Unit (GC40015LNT)
SeriesGC400 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/2" (NPT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeNot fitted
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC400-15 FRL Unit (GC40015LNT)

GC400G-series F.R.L. combination, 400 body — sets the port range.
15Port size PT1/2". This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
NNo pressure gauge (N).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-15 filter, GR400-15 regulator and GL400-15 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC400 · PT1/2" · 40 µm
One size downGC300
One size upGC600
Two-unit equivalentGFC400-15
Build orderFilter → regulator → lubricator

Where the AirTAC GC400-15 FRL Unit (GC40015LNT) Is Used

air

Air-knife drying line

Feeds filtered, low-pressure regulated air to air knives that blow water off bottles or cans on a bottling conveyor before labelling, with the lubricator protecting any downstream pneumatics on the same line.

factory

Textile air-jet loom supply

Conditions the compressed air feeding weft-insertion jets on an air-jet weaving loom, where the low-pressure regulator type matches the low working pressure the loom's air circuit runs at.

conveyor_belt

Packaging conveyor cylinders

Cleans, regulates and lubricates the air supply to carton-flap tuck and pusher cylinders on a packaging conveyor, keeping moisture and particles out of the valve manifold.

Is the AirTAC GC400-15 FRL Unit (GC40015LNT) the Right Station?

Choose size 400 (NPT1/2) when a 1/2 inch main feeds several cylinders or a larger actuator; the smaller GC200 and GC300 sets cover lighter duty. The L in this code marks the low-pressure type of the regulator section, intended for circuits where the working pressure sits well below normal shop-air settings - send us your set pressure and we will confirm the adjusting range on the datasheet before you order. Drain here is the differential-pressure default; automatic (A) and manual (M) versions exist in the series. Filter grade is the standard 40 um; specify W for 5 um. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. A gauge can be added as an embedded square or external round unit if you want a visual setpoint.

Because G-series flow is published as curves and not as a single rated figure, we do not quote a flow number here. Ask us to confirm sizing of the GC40015LNT against your application and the AirTAC datasheet before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-15 regulator with a GF400-15 filter on that branch.

AirTAC GC400-15 FRL Unit (GC40015LNT) FAQ

AirTAC publishes G-series flow as performance curves, not as a single rated figure, so we do not quote a flow number on the page. Tell us your air demand and line pressure and we will confirm the sizing from the datasheet on request before you order.

L marks the low-pressure type of the regulator section, used where the downstream working pressure is well below normal shop-air settings. If your circuit regulates around standard pressures, the version without L is the usual choice; we can confirm the right type and its adjusting range from the datasheet on request.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GC400-15 FRL Unit (GC40015LNT)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GC40015LNT and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.