AirTAC GC400 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC400-15 FRL Unit (GC40015LNTK)

The AirTAC GC400-15 FRL Unit (GC40015LNTK) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/2" ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/2"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeNot fitted
  • ThreadNPT
$162.62 $170.12Save 4% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GC400-15 drain, gauge and thread option on one page All GC400-15 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GC400-15 FRL Unit (GC40015LNTK)

The GC40015LNTK is a three-piece AirTAC G-series F.R.L. combination - separate air filter, pressure regulator and lubricator - supplied in size 400 with NPT1/2 ports and a NPT thread. The K in the code means a reverse (check) valve is fitted in the regulator section, so downstream pressure is held if the upstream supply dips. This version is the low-pressure type with no gauge, a standard 40 um filter element, and a differential-pressure drain on the polycarbonate (PC) filter bowl.

This is a genuine AirTAC part. The G-series spans sizes 200 to 600 with options including automatic or manual drains, a 5 um element, embedded square or external round gauges, and G (BSPP) or NPT threads as catalogue choices. Maximum working pressure is 1.0 MPa (145 psi); operating temperature is -5 to 70 C, non-freezing. Flow is published as curves rather than a single rating, so we confirm figures from the datasheet on request.

AirTAC GC400-15 FRL Unit (GC40015LNTK) Technical Specifications

ModelAirTAC GC400-15 FRL Unit (GC40015LNTK)
SeriesGC400 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/2" (NPT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeNot fitted
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC400-15 FRL Unit (GC40015LNTK)

GC400G-series F.R.L. combination, 400 body — sets the port range.
15Port size PT1/2". This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
NNo pressure gauge (N).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-15 filter, GR400-15 regulator and GL400-15 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC400 · PT1/2" · 40 µm
One size downGC300
One size upGC600
Two-unit equivalentGFC400-15
Build orderFilter → regulator → lubricator

Where the AirTAC GC400-15 FRL Unit (GC40015LNTK) Is Used

bolt

Pneumatic clamping fixture

Supplies filtered, low-pressure regulated air to clamping cylinders on a machining cell, where the fitted check valve helps hold the clamp circuit while the upstream supply fluctuates.

settings_input_component

Pick-and-place module

Conditions the air feeding a pick-and-place handling module on an assembly line, keeping particles and water out of the valve island while the lubricator mists the actuators' air.

engineering

Test-rig actuation skid

Provides clean, regulated, lubricated air to the actuated cylinders on a low-pressure test rig, with the check valve holding the set circuit pressure during supply interruptions.

Is the AirTAC GC400-15 FRL Unit (GC40015LNTK) the Right Station?

Pick this model over the plain GC40015LN when a supply-side pressure dip must not dump your regulated downstream pressure - the fitted check valve holds the circuit while the upstream side recovers, useful on clamping and holding circuits. Size 400 with NPT1/2 ports suits a 1/2 inch main feeding multiple actuators. The L marks the low-pressure regulator type; give us your set pressure and we will confirm the adjusting range on the datasheet. Drain is the differential-pressure default (automatic A and manual M exist). Filter grade is 40 um standard, 5 um with W. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. G (BSPP) and NPT (T) are orderable options, and a square or round gauge can be added.

Flow for G-series units is published as curves, not a single rated figure, so send your flow demand and we will confirm sizing against the AirTAC datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-15 regulator with a GF400-15 filter on that branch.

AirTAC GC400-15 FRL Unit (GC40015LNTK) FAQ

We do not state a rated flow number because AirTAC publishes G-series flow as curves rather than a single rating. Share your application's flow and pressure and we will confirm the sizing from the datasheet on request before you order.

K means a reverse (check) valve is fitted in the regulator section. It blocks reverse flow, so the regulated downstream pressure is held if the upstream supply drops - the plain GC40015LN without K has no check valve. We can confirm details on the datasheet on request.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GC400-15 FRL Unit (GC40015LNTK)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GC40015LNTK and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.