verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC400 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC400-15 FRL Unit (GC40015MC1T)

The AirTAC GC400-15 FRL Unit (GC40015MC1T) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/2" ports, a 40 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/2"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade40 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$155.22 $162.72Save 4% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GC400-15 drain, gauge and thread option on one page All GC400-15 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GC400-15 FRL Unit (GC40015MC1T)

The GC40015MC1T is a three-piece AirTAC G-series F.R.L. combination - separate air filter, pressure regulator and lubricator - in size 400 with NPT1/2 ports and a NPT thread. The M selects a manual drain on the polycarbonate (PC) filter bowl, so collected water is released by operating the drain by hand. The standard regulator type covers the usual 0.05-0.9 MPa (7-130 psi) adjusting range for manual-drain units, and the C1 option adds an external round gauge with an MPa scale for a clear setpoint readout. The filter element is the standard 40 um grade.

This is a genuine AirTAC part. The G-series runs from size 200 to 600, with differential-pressure or automatic drain options, a 5 um filter element, embedded square or external round gauges, and G (BSPP) or NPT threads as catalogue choices. Maximum working pressure is 1.0 MPa (145 psi); operating temperature is -5 to 70 C, non-freezing. Flow is published as curves rather than a single rating, so we confirm figures from the datasheet on request.

AirTAC GC400-15 FRL Unit (GC40015MC1T) Technical Specifications

ModelAirTAC GC400-15 FRL Unit (GC40015MC1T)
SeriesGC400 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/2" (NPT thread)
Filtering grade40 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeFitted — round, MPa scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC400-15 FRL Unit (GC40015MC1T)

GC400G-series F.R.L. combination, 400 body — sets the port range.
15Port size PT1/2". This body offers 10 = PT3/8", 15 = PT1/2".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-15 filter, GR400-15 regulator and GL400-15 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC400 · PT1/2" · 40 µm
One size downGC300
One size upGC600
Two-unit equivalentGFC400-15
Build orderFilter → regulator → lubricator

Where the AirTAC GC400-15 FRL Unit (GC40015MC1T) Is Used

factory

Stamping press air supply

Conditions the air feeding clutch, counterbalance and part-ejection circuits on a stamping press, with the MPa round gauge letting the setter read the regulated pressure at a glance.

local_shipping

Trailer assembly stations

Filters, regulates and lubricates the air at assembly-station outlets driving impact wrenches and pneumatic ratchets on truck and trailer assembly lines, with manual blow-down of collected water between shifts.

build

Spray booth air preparation

Prepares the air feeding spray guns in a paint booth: the 40 um element removes water and particles, the regulator sets gun pressure read on the round gauge, and the lubricator is bypassed or set per gun requirements.

Is the AirTAC GC400-15 FRL Unit (GC40015MC1T) the Right Station?

Choose the manual drain (M) when an operator is already at the machine and a scheduled blow-down fits the routine; pick the automatic drain version if the unit sits in an inaccessible spot. With manual drain, the regulator's adjusting range is 0.05-0.9 MPa (7-130 psi). The C1 code fits an external round gauge reading in MPa; square embedded gauges and other scale options exist in the series. Size 400 with NPT1/2 ports suits a 1/2 inch main feeding multiple actuators; step down to GC200 or GC300 for lighter duty. Filter grade is 40 um standard, 5 um with W. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes.

Flow for G-series units is published as curves, not a single rated figure, so send us your flow demand and we will confirm sizing against the AirTAC datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-15 regulator with a GF400-15 filter on that branch.

AirTAC GC400-15 FRL Unit (GC40015MC1T) FAQ

We do not quote a rated flow number because AirTAC publishes G-series flow as performance curves rather than a single rating. Give us your air demand and line pressure and we will confirm the sizing from the datasheet on request before you order.

M selects the manual drain, so water in the filter bowl is drained by hand - this version's regulator adjusts over 0.05-0.9 MPa (7-130 psi). C1 fits an external round gauge with an MPa scale. If you prefer automatic drainage or a different scale, those are catalogue options in the same series.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GC400-15 FRL Unit (GC40015MC1T)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GC40015MC1T and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.