verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC400 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC400-15 FRL Unit (GC40015MC2T)

The AirTAC GC400-15 FRL Unit (GC40015MC2T) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/2" ports, a 40 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/2"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade40 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$155.22 $162.72Save 4% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GC400-15 drain, gauge and thread option on one page All GC400-15 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GC400-15 FRL Unit (GC40015MC2T)

The AirTAC GC400-15 is a three-piece F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one unit. It removes water and particulate down to 40 um, regulates downstream pressure across 0.05-0.9 MPa (7-130 psi), and meters oil mist to keep downstream air tools lubricated. This configuration has a NPT1/2 (1/2 in) port with NPT thread, a manual drain on the filter bowl, a fitted round pressure gauge reading in psi, and a polycarbonate bowl (size 600 units use aluminium alloy). Maximum inlet pressure is 1.0 MPa (145 psi); operating temperature is -5 to 70 C, non-freezing. A mounting bracket is included.

This is a genuine AirTAC part. The GC series is available in sizes 200, 300, 400 and 600 with port sizes from 1/8 in to 1 in, and options including 5 um filtration (code W), automatic or differential-pressure drains, G (BSPP) or NPT threads, and MPa, psi or bar gauge scales. Flow is published as curves rather than a single rated figure, so ask us to confirm datasheet figures for your application before ordering. Order code GC40015MC2T has NPT ports (the T in the code) for North American pipe fittings.

AirTAC GC400-15 FRL Unit (GC40015MC2T) Technical Specifications

ModelAirTAC GC400-15 FRL Unit (GC40015MC2T)
SeriesGC400 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/2" (NPT thread)
Filtering grade40 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeFitted — round, psi scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC400-15 FRL Unit (GC40015MC2T)

GC400G-series F.R.L. combination, 400 body — sets the port range.
15Port size PT1/2". This body offers 10 = PT3/8", 15 = PT1/2".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-15 filter, GR400-15 regulator and GL400-15 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC400 · PT1/2" · 40 µm
One size downGC300
One size upGC600
Two-unit equivalentGFC400-15
Build orderFilter → regulator → lubricator

Where the AirTAC GC400-15 FRL Unit (GC40015MC2T) Is Used

factory

Automotive assembly stations

Supplies impact wrenches and air ratchets on an assembly line with water- and particulate-filtered air at a set pressure, plus oil mist to keep the tools lubricated through a full shift.

conveyor_belt

Packaging machinery air supply

Feeds carton sealers, case erectors and wrapping heads on a packaging line with clean, regulated, lubricated air so cylinders and actuators cycle consistently at the set pressure.

precision_manufacturing

Machine shop pneumatic clamping

Serves milling and turning cells where pneumatic clamps, tool changers and workholding fixtures need moisture-removed air held at a stable, adjustable pressure.

Is the AirTAC GC400-15 FRL Unit (GC40015MC2T) the Right Station?

Size 400 with a NPT1/2 port suits lines plumbed at 1/2 in; step up or down a size if your flow demand or piping changes. Because flow is published as curves and not a single rating, ask us to confirm sizing against your application before ordering. This unit has a manual drain, which you open periodically to clear collected water; automatic and differential-pressure drain variants exist in the range if you prefer hands-off draining. The 40 um element is the standard grade; specify 5 um (code W) where finer particulate removal matters. The fitted round gauge reads psi, with MPa and bar scales available as alternatives. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-15 regulator with a GF400-15 filter on that branch.

AirTAC GC400-15 FRL Unit (GC40015MC2T) FAQ

Flow for the GC400-15 is published in the AirTAC datasheet as curves rather than a single rated number, so we do not quote a figure here. Send us your application details and we will confirm the flow and sizing data on request before you order.

This unit has a manual drain: open it periodically to release the water that collects in the filter bowl. If you prefer not to drain by hand, the GC range is also available with automatic or differential-pressure drains - ask us for the correct variant code.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GC400-15 FRL Unit (GC40015MC2T)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GC40015MC2T and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.