The AirTAC GC400-15 FRL Unit (GC40015MC3WTK) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/2" ports, a 5 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).
The AirTAC GC series is a three-piece F.R.L. combination: a separate air filter, pressure regulator and lubricator built as one air-preparation set. This GC40015MC3WTK is the 400 size with 1/2 in NPT ports, a manual drain, the fine 5 um filter element (W), a fitted reverse (check) valve (K) and a round pressure gauge reading in bar. The finer element and check valve make it the version to specify where downstream valves are sensitive or where backflow must be blocked.
This is a genuine AirTAC part rated to 1.0 MPa (145 psi) inlet, with a manual-drain regulation range of 0.05-0.9 MPa (7-130 psi) and a working temperature of -5 to 70 C, non-freezing. The G series is available in 200, 300, 400 and 600 sizes with drain, filter-grade, gauge and thread options. Flow is published as curves rather than a single figure, so ask us to confirm the datasheet and sizing for your application on request.
| Model | AirTAC GC400-15 FRL Unit (GC40015MC3WTK) |
|---|---|
| Series | GC400 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | PT1/2" (NPT thread) |
| Filtering grade | 5 µm |
| Regulating range | 0.05 - 0.9 MPa (7 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Manual drain |
| Bowl material | PC |
| Pressure gauge | Fitted — round, bar scale |
| Reflux valve | Fitted (reverse flow permitted) |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC400 | G-series F.R.L. combination, 400 body — sets the port range. |
|---|---|
| 15 | Port size PT1/2". This body offers 10 = PT3/8", 15 = PT1/2". |
| M | Drain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| C | Gauge shape: Round. C is round, F is square. |
| 3 | Gauge scale: bar. 1 is MPa, 2 is psi, 3 is bar. |
| W | Filtering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| K | Reverse-flow (reflux) valve fitted. |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-15 filter, GR400-15 regulator and GL400-15 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC400 · PT1/2" · 5 µm |
|---|---|
| One size down | GC300 |
| One size up | GC600 |
| Two-unit equivalent | GFC400-15 |
| Build order | Filter → regulator → lubricator |
Feeds filtered 5 um air to the weld-gun clamp and boost cylinders of a robotic spot-welding cell, with the check valve blocking backflow when the supply dips.
Prepares fine-filtered, regulated and lubricated air for the compact solenoid valves and gripper cylinders of an electronics assembly pick-and-place module.
Supplies regulated air to workholding clamp cylinders on a machining fixture, where the reverse valve helps hold the downstream circuit if upstream pressure is lost.
Choose this code over the plain GC40015MC3 when two things matter: the W suffix fits a 5 um element instead of the standard 40 um, protecting fine solenoid valves and precision tools, and the K suffix adds a reverse (check) valve to the set. The 400 size with 1/2 in NPT ports suits a single set feeding several downstream users; confirm against the flow curve before ordering. Manual drain suits attended installations; pick A or blank (differential-pressure) drain for unattended ones. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. the gauge reads in bar and MPa or psi scales are available.
Because flow is published as curves, not a single rating, send us your duty point and we will confirm sizing from the datasheet on request.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-15 regulator with a GF400-15 filter on that branch.
We do not quote a single rated-flow number because AirTAC publishes GC-series flow as performance curves that vary with pressure and porting. Give us your operating pressure and required consumption and we will confirm the sizing from the datasheet on request before you order.
The 40 um element is the standard choice for general cylinders and air tools. The 5 um element in this code is the option for applications with fine solenoid valves, precision pneumatic components or sensitive downstream equipment that needs cleaner air. Both are catalogue options across the GF/GFR/GFC/GC families, so you can step up or down at any size.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.