AirTAC GC400 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC400-15 FRL Unit (GC40015MLF2WTK)

The AirTAC GC400-15 FRL Unit (GC40015MLF2WTK) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/2" ports, a 5 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/2"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade5 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$170.15 $177.65Save 4% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GC400-15 drain, gauge and thread option on one page All GC400-15 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GC400-15 FRL Unit (GC40015MLF2WTK)

The AirTAC GC40015MLF2WTK is a three-unit F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one GC400 unit. It conditions compressed air in a single installation step - the filter removes water and particulate down to 5 um (the W fine-grade element, versus the standard 40 um), the low-pressure-type regulator holds a set downstream pressure, and the lubricator adds oil mist for downstream air tools and cylinders. This configuration has a NPT1/2 (1/2 in) port with NPT thread, a manual drain on the filter bowl, an embedded square gauge reading in psi, a reverse/check valve fitted, and a mounting bracket included. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C (non-freezing).

This is a genuine AirTAC part. The GC series is available in sizes 200, 300, 400 and 600 with port sizes from 1/8 in to 1 in, and with choices of drain type, filter grade, gauge scale, thread (NPT on this code) and reverse/check valve. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet and sizing for your application before ordering.

AirTAC GC400-15 FRL Unit (GC40015MLF2WTK) Technical Specifications

ModelAirTAC GC400-15 FRL Unit (GC40015MLF2WTK)
SeriesGC400 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/2" (NPT thread)
Filtering grade5 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeFitted — square, psi scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC400-15 FRL Unit (GC40015MLF2WTK)

GC400G-series F.R.L. combination, 400 body — sets the port range.
15Port size PT1/2". This body offers 10 = PT3/8", 15 = PT1/2".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-15 filter, GR400-15 regulator and GL400-15 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC400 · PT1/2" · 5 µm
One size downGC300
One size upGC600
Two-unit equivalentGFC400-15
Build orderFilter → regulator → lubricator

Where the AirTAC GC400-15 FRL Unit (GC40015MLF2WTK) Is Used

factory

Packaging line air supply

Feeding a wrapper or cartoner's cylinder and valve bank: the 5 um element keeps water and fine dirt out of the valves, the regulator sets line pressure and the lubricator mists oil to the actuators - all from one NPT1/2 drop.

conveyor_belt

Conveyor drive and clamping air

Supplying air to conveyor gate cylinders and hold-down clamps on a bottling or food-handling line, where the manual-drain filter bowl is serviced during shift checks and the psi gauge gives operators a visible setpoint.

build

Workshop tool-air drop

A 1/2 in service drop feeding impact wrenches, grinders and air motors in a maintenance shop: fine filtration protects the tools, the low-pressure-type regulator matches the tool rating, and oil mist lubrication runs the tool motors.

Is the AirTAC GC400-15 FRL Unit (GC40015MLF2WTK) the Right Station?

Size 400 with a NPT1/2 port sits in the upper-middle of the GC range; step up to size 600 or down to 300 depending on the flow your line needs - we will check the published flow curves against your demand if you send the figures. This unit is the fine-filtration build (5 um, code W) rather than the 40 um standard element, so choose it where downstream valves and cylinders need cleaner air. The drain is manual, meaning an operator opens the drain periodically rather than relying on an automatic or differential-pressure arrangement - pick automatic or differential-drain variants if the unit is mounted where regular access is difficult. The regulator is the low-pressure type; its exact adjustment range is not published in the material we hold, so confirm it with us against your set pressure. The square gauge reads in psi (MPa and bar scales exist as alternatives), a reverse/check valve is fitted, and the bracket is included. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. G and NPT are order options. Because flow is published as curves and not a single rating, ask us to confirm sizing against the application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-15 regulator with a GF400-15 filter on that branch.

AirTAC GC400-15 FRL Unit (GC40015MLF2WTK) FAQ

AirTAC publishes flow for the GC400 series as curves rather than a single rated figure, so we do not quote one number. Send us your line pressure and the air demand of the equipment you are feeding, and we will confirm the sizing from the datasheet before you order.

The M in the code is the manual drain: an operator opens the filter bowl drain periodically instead of relying on an automatic or differential-pressure drain, which suits units mounted where they are checked routinely. The W is the 5 um fine-grade filter element, chosen over the 40 um standard when downstream valves and cylinders need cleaner air. Both are decodable choices you can order differently within the GC series.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GC400-15 FRL Unit (GC40015MLF2WTK)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GC40015MLF2WTK and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.