The AirTAC GC400-15 FRL Unit (GC40015MLF2WTK) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/2" ports, a 5 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).
The AirTAC GC40015MLF2WTK is a three-unit F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one GC400 unit. It conditions compressed air in a single installation step - the filter removes water and particulate down to 5 um (the W fine-grade element, versus the standard 40 um), the low-pressure-type regulator holds a set downstream pressure, and the lubricator adds oil mist for downstream air tools and cylinders. This configuration has a NPT1/2 (1/2 in) port with NPT thread, a manual drain on the filter bowl, an embedded square gauge reading in psi, a reverse/check valve fitted, and a mounting bracket included. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C (non-freezing).
This is a genuine AirTAC part. The GC series is available in sizes 200, 300, 400 and 600 with port sizes from 1/8 in to 1 in, and with choices of drain type, filter grade, gauge scale, thread (NPT on this code) and reverse/check valve. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet and sizing for your application before ordering.
| Model | AirTAC GC400-15 FRL Unit (GC40015MLF2WTK) |
|---|---|
| Series | GC400 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | PT1/2" (NPT thread) |
| Filtering grade | 5 µm |
| Regulating range | 0.05 - 0.9 MPa (7 - 130 psi) |
| Pressure type | Low-pressure type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Manual drain |
| Bowl material | PC |
| Pressure gauge | Fitted — square, psi scale |
| Reflux valve | Fitted (reverse flow permitted) |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC400 | G-series F.R.L. combination, 400 body — sets the port range. |
|---|---|
| 15 | Port size PT1/2". This body offers 10 = PT3/8", 15 = PT1/2". |
| M | Drain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)). |
| L | Low-pressure type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 2 | Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar. |
| W | Filtering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| K | Reverse-flow (reflux) valve fitted. |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-15 filter, GR400-15 regulator and GL400-15 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC400 · PT1/2" · 5 µm |
|---|---|
| One size down | GC300 |
| One size up | GC600 |
| Two-unit equivalent | GFC400-15 |
| Build order | Filter → regulator → lubricator |
Feeding a wrapper or cartoner's cylinder and valve bank: the 5 um element keeps water and fine dirt out of the valves, the regulator sets line pressure and the lubricator mists oil to the actuators - all from one NPT1/2 drop.
Supplying air to conveyor gate cylinders and hold-down clamps on a bottling or food-handling line, where the manual-drain filter bowl is serviced during shift checks and the psi gauge gives operators a visible setpoint.
A 1/2 in service drop feeding impact wrenches, grinders and air motors in a maintenance shop: fine filtration protects the tools, the low-pressure-type regulator matches the tool rating, and oil mist lubrication runs the tool motors.
Size 400 with a NPT1/2 port sits in the upper-middle of the GC range; step up to size 600 or down to 300 depending on the flow your line needs - we will check the published flow curves against your demand if you send the figures. This unit is the fine-filtration build (5 um, code W) rather than the 40 um standard element, so choose it where downstream valves and cylinders need cleaner air. The drain is manual, meaning an operator opens the drain periodically rather than relying on an automatic or differential-pressure arrangement - pick automatic or differential-drain variants if the unit is mounted where regular access is difficult. The regulator is the low-pressure type; its exact adjustment range is not published in the material we hold, so confirm it with us against your set pressure. The square gauge reads in psi (MPa and bar scales exist as alternatives), a reverse/check valve is fitted, and the bracket is included. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. G and NPT are order options. Because flow is published as curves and not a single rating, ask us to confirm sizing against the application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-15 regulator with a GF400-15 filter on that branch.
AirTAC publishes flow for the GC400 series as curves rather than a single rated figure, so we do not quote one number. Send us your line pressure and the air demand of the equipment you are feeding, and we will confirm the sizing from the datasheet before you order.
The M in the code is the manual drain: an operator opens the filter bowl drain periodically instead of relying on an automatic or differential-pressure drain, which suits units mounted where they are checked routinely. The W is the 5 um fine-grade filter element, chosen over the 40 um standard when downstream valves and cylinders need cleaner air. Both are decodable choices you can order differently within the GC series.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.