verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GF300 · Air Filter (water separation + particulate filtration)

AirTAC GF300-15 Filter (GF30015MJ)

The AirTAC AirTAC GF300-15 Filter (GF30015MJ) is a genuine G-series air filter. It separates condensed water and filters particulate from the compressed-air line through a 40 µm element, with PT1/2" ports and a manual drain. A filter does not set downstream pressure — pair it with a GR regulator, or use a GFR filter regulator, when pressure control is needed.

  • TypeAir filter
  • Port sizePT1/2"
  • Filtering grade40 µm
  • DrainManual drain
  • Inlet pressure0 - 0.9 MPa (0 - 131 psi)
  • Bowl materialPC
  • ThreadPT
  • BracketSupplied without bracket
$26.39 $30.73Save 14% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GF300 stroke, mounting and version on one page All GF300 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC GF300-15 Filter (GF30015MJ)

The AirTAC GF30015MJ is a G-series compressed-air filter: it removes water and particulate from the air line only - no regulation, no lubrication. This configuration is size 300 with a 1/2 in PT (the standard thread) port, a polycarbonate manual-drain bowl and the standard 40 um element, and the J suffix means no mounting bracket is supplied. Maximum inlet pressure for the manual-drain version is 0.9 MPa.

It is a genuine AirTAC part. The GF family runs from size 200 to 600 with port, thread (PT/G/NPT), drain (manual, automatic, differential-pressure) and element (40 um standard, 5 um with W) options, and bracket versions are available if you want one. Flow is published as curves rather than a single rating, so we confirm datasheet and flow figures on request.

AirTAC GF300-15 Filter (GF30015MJ) Technical Specifications

ModelAirTAC GF300-15 Filter (GF30015MJ)
SeriesGF300 air filter
Port sizePT1/2" (PT thread)
Filtering grade40 µm
Drain typeManual drain
BracketSupplied without bracket
FluidCompressed air
Inlet pressure0 - 0.9 MPa (0 - 131 psi)
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Bowl materialPC
FeatureLow pressure loss

Specifications follow the official AirTAC G-series air-preparation data. The inlet-pressure band is set by the drain type: automatic and differential-pressure drains run 0.15 - 1.0 MPa, a manual drain runs 0 - 0.9 MPa. Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GF300-15 Filter (GF30015MJ)

GF300G-series air filter, 300 body — sets the port range.
15Port size PT1/2". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
MDrain: Manual drain. Options are differential (blank), automatic (A) or manual (M).
JSupplied without bracket. A bracket ships by default; J orders it without.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.

Field order is size, port, drain, bracket, grade, thread — a blank position takes the default. Example: GF300-10AJW is a 300 body, PT3/8", automatic drain, no bracket, 5 µm element, PT thread.

Size Class

  • GF200PT1/8" - PT1/4"
  • GF300PT1/4" - PT1/2"
  • GF400PT3/8" - PT1/2"
  • GF600PT3/4" - PT1"

A larger body carries a larger port and passes more air at the same pressure drop. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom rather than from a single rated figure. The GF600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGF300 · PT1/2" · 40 µm
One size downGF200
One size upGF400
Line orderFilter first, then regulator, then lubricator

Where the AirTAC GF300-15 Filter (GF30015MJ) Is Used

settings_input_component

Pneumatic control panel feed

Fitted on the supply stub inside a control panel that feeds solenoid valves and air piloted devices, it keeps moisture and debris out of the valve stack where a bracket is not needed.

build

Air tool drop at a maintenance bench

Installed at a workshop bench outlet ahead of impact wrenches, ratchets and blow guns, it dries the shop air so the tools and quick couplings last longer.

local_shipping

Truck and bus service bay air line

Placed on the bench air supply in a commercial-vehicle workshop, it removes water from the line before it reaches tyre inflators, air chisels and brake-test equipment.

Is the AirTAC GF300-15 Filter (GF30015MJ) the Right Filter?

This is the size 300, 1/2 in port filter in the no-bracket (J) configuration - pick the bracketed GF30015M if you want wall or panel mounting hardware in the box, or this one if you are installing inline or on existing hardware. The manual drain suits installations someone can walk up to; automatic or differential-pressure drain variants exist for unattended positions. The 40 um element is the general-purpose grade; the W variant gives 5 um for finer protection. PT is the standard thread, with G and NPT as order options.

Filter flow appears as curves, not one rated figure, so ask us to confirm the datasheet and sizing for your air demand before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain: differential, automatic or manual
  • ✓ Manual drain caps inlet at 0.9 MPa
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Bracket needed, or order with J
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, and follow the airflow arrow.
  • check Put the filter first in the air-preparation line.
  • check Keep inlet pressure within 0 - 0.9 MPa (0 - 131 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).
  • check Replace the 40 µm element when pressure loss rises.

The PC bowl must not be cleaned with solvents or exposed to synthetic oils that attack polycarbonate — wipe it with a dry cloth. A filter removes water and particulate only; it does not regulate pressure or add lubrication.

AirTAC GF300-15 Filter (GF30015MJ) FAQ

There is no single rated-flow figure for this filter - AirTAC publishes flow as pressure-drop curves only. Send us your line pressure and consumption and we will confirm suitability from the datasheet on request.

No - J only removes the mounting bracket. Function, size 300, 1/2 in PT port, manual drain and the 40 um element are all identical to the bracketed GF30015M, and a bracketed version is available if you later need to panel-mount the filter.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC GF300-15 Filter (GF30015MJ)

Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GF30015MJ and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.