verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GF300 · Air Filter (water separation + particulate filtration)

AirTAC GF300-15 Filter (GF30015AJT)

The AirTAC GF300-15 Filter (GF30015AJT) is a genuine G-series air filter. It separates condensed water and filters particulate from the compressed-air line through a 40 µm element, with PT1/2" ports and a automatic drain. A filter does not set downstream pressure — pair it with a GR regulator, or use a GFR filter regulator, when pressure control is needed.

  • TypeAir filter
  • Port sizePT1/2"
  • Filtering grade40 µm
  • DrainAutomatic drain
  • Inlet pressure0.15 - 1.0 MPa (22 - 145 psi)
  • Bowl materialPC
  • ThreadNPT
  • BracketSupplied without bracket
$40.55 $48.05Save 15% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GF300 stroke, mounting and version on one page All GF300 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GF300-15 Filter (GF30015AJT)

GF30015AJT is an AirTAC G-series GF air filter: filtration only, removing water and particulate from the compressed-air line, with no pressure regulation and no lubrication. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. The J suffix means no mounting bracket is supplied, so the unit mounts directly by its port, and it is rated for 1.0 MPa (145 psi) maximum working pressure at -5 to 70 C (non-freezing).

This is a genuine AirTAC part. The GF filter family spans sizes 200, 300, 400 and 600 with ports from 1/8 to 1 in, 40 um standard or 5 um (W) filtration, a choice of differential-pressure, automatic (A) or manual (M) drain, and three thread types (NPT on this code). Flow is published as curves rather than a single rated figure, so ask us and we will confirm the datasheet and sizing for your application.

AirTAC GF300-15 Filter (GF30015AJT) Technical Specifications

ModelAirTAC GF300-15 Filter (GF30015AJT)
SeriesGF300 air filter
Port sizePT1/2" (NPT thread)
Filtering grade40 µm
Drain typeAutomatic drain
BracketSupplied without bracket
FluidCompressed air
Inlet pressure0.15 - 1.0 MPa (22 - 145 psi)
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Bowl materialPC
FeatureLow pressure loss

Specifications follow the official AirTAC G-series air-preparation data. The inlet-pressure band is set by the drain type: automatic and differential-pressure drains run 0.15 - 1.0 MPa, a manual drain runs 0 - 0.9 MPa. Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GF300-15 Filter (GF30015AJT)

GF300G-series air filter, 300 body — sets the port range.
15Port size PT1/2". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
ADrain: Automatic drain. Options are differential (blank), automatic (A) or manual (M).
JSupplied without bracket. A bracket ships by default; J orders it without.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.

Field order is size, port, drain, bracket, grade, thread — a blank position takes the default. Example: GF300-10AJW is a 300 body, PT3/8", automatic drain, no bracket, 5 µm element, PT thread.

Size Class

  • GF200PT1/8" - PT1/4"
  • GF300PT1/4" - PT1/2"
  • GF400PT3/8" - PT1/2"
  • GF600PT3/4" - PT1"

A larger body carries a larger port and passes more air at the same pressure drop. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom rather than from a single rated figure. The GF600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGF300 · PT1/2" · 40 µm
One size downGF200
One size upGF400
Line orderFilter first, then regulator, then lubricator

Where the AirTAC GF300-15 Filter (GF30015AJT) Is Used

settings_input_component

Control cabinet air preparation

Mount by its ports inside a control cabinet ahead of solenoid valves, filtering branch air with automatic drainage while the bracketless body saves panel space.

valve

Process skid instrument air

Fit inline on the instrument-air takeoff of a process skid, where the automatic drain handles condensate and pipework mounting replaces the need for a bracket.

speed

Automated assembly cell supply

Use on the supply to an automated assembly cell, feeding air cylinders and pick-and-place actuators with filtered air that drains itself between shifts.

Is the AirTAC GF300-15 Filter (GF30015AJT) the Right Filter?

Choose the GF size from 200 (1/8-1/4 in), 300 (3/8-1/2 in), 400 (1/2-3/4 in) and 600 (3/4-1 in) against your line and the published flow curve. This configuration pairs the A-coded automatic drain with the J suffix, so it is supplied without a mounting bracket - order the bracketed version if you need panel or wall fixing. The standard 40 um element can be swapped for the W-coded 5 um grade; drain alternatives are the default differential-pressure type and the M-coded manual drain. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Flow appears only as curves, not a single rating, so ask us to confirm sizing before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain: differential, automatic or manual
  • ✓ Manual drain caps inlet at 0.9 MPa
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Bracket needed, or order with J
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, and follow the airflow arrow.
  • check Put the filter first in the air-preparation line.
  • check Keep inlet pressure within 0.15 - 1.0 MPa (22 - 145 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).
  • check Replace the 40 µm element when pressure loss rises.

The PC bowl must not be cleaned with solvents or exposed to synthetic oils that attack polycarbonate — wipe it with a dry cloth. A filter removes water and particulate only; it does not regulate pressure or add lubrication.

AirTAC GF300-15 Filter (GF30015AJT) FAQ

There is no single rated figure to quote: AirTAC publishes G-series filter flow as performance curves. Send us your working pressure and air demand and we will confirm the datasheet curve and correct sizing on request before you order.

The J suffix deletes the mounting bracket that normally comes with the GF body, so the filter is supplied for direct port mounting. Everything else in the code stays the same: size 300, NPT1/2 in port, 40 um element and A-coded automatic drain.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GF300-15 Filter (GF30015AJT)

Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GF30015AJT and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.