verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GFC200 · Two-Unit Set (filter regulator + lubricator)

AirTAC GFC200-08 Combination Unit (GFC20008F1T)

The AirTAC GFC200-08 Combination Unit (GFC20008F1T) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/4" ports, a 40 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizePT1/4"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$59.60 $67.10Save 11% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GFC200-08 drain, gauge and thread option on one page All GFC200-08 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GFC200-08 Combination Unit (GFC20008F1T)

The AirTAC GFC20008F1T is a two-unit air-treatment set that combines a filter regulator and a separate lubricator in one matched pair, so the air is filtered, regulated and then oil-mist lubricated before it reaches your actuators. This 200-size configuration is specified for 1/4 inch NPT ports. The filter bowl uses the default differential-pressure drain, the element is the standard 40 um grade, and the regulator is the standard type with the embedded square gauge reading in MPa.

This is a genuine AirTAC part. The G series is offered in sizes 200, 300, 400 and 600 with a choice of ports, thread options, drain types and 40 um or 5 um elements. Max working pressure is 1.0 MPa (145 psi), operating temperature is -5 to 70 C (non-freezing), and the PC bowl suits this size. Flow is published as curves rather than a single rating, so we confirm the datasheet and sizing figures on request.

AirTAC GFC200-08 Combination Unit (GFC20008F1T) Technical Specifications

ModelAirTAC GFC200-08 Combination Unit (GFC20008F1T)
SeriesGFC200 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizePT1/4" (NPT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — square, MPa scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GFC200-08 Combination Unit (GFC20008F1T)

GFC200G-series two-unit set, 200 body — sets the port range.
08Port size PT1/4". This body offers 06 = PT1/8", 08 = PT1/4".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR200-08 filter regulator and GL200-08 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC200 · PT1/4" · 40 µm
One size upGFC300
Three-unit equivalentGC200-08
Build orderFilter regulator first, lubricator last

Where the AirTAC GFC200-08 Combination Unit (GFC20008F1T) Is Used

settings_input_component

Packaging machine valve island

Feeds clean, regulated, lubricated air to the directional valves and cylinders of a cartoning or case-packing machine, with the lubricator keeping downstream sealing parts misted for long shift running.

build

Pneumatic clamping fixture

Supplies a workholding clamp circuit on a machining fixture, where the regulator holds steady clamp pressure and the filter removes water and particulate before the air reaches the clamping cylinders.

conveyor_belt

Conveyor diverters and stoppers

Prepares the air supply for pop-up diverters, stoppers and pushers on a sortation conveyor, conditioning the air once at the drop and feeding the whole control group downstream.

Is the AirTAC GFC200-08 Combination Unit (GFC20008F1T) the Right Set?

Start by matching the 200 size and its 1/4 inch port to your line demand - larger 300/400/600 sizes give larger ports and more flow. Choose the drain style for the filter bowl: differential-pressure (this model), automatic (A) for unattended draining, or manual (M) where you drain on a schedule. Pick the element grade: 40 um standard here, or W for 5 um finer filtration. The regulator covers 0.15-0.9 MPa (20-130 psi) with this differential-pressure drain, and the F1 code gives the embedded square gauge in MPa - other gauge scales and styles are available. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. G (BSPP) and NPT are catalogue options. Add K if you want a reverse/check valve fitted.

Because flow is published as curves and not a single rated number, ask us to confirm sizing against your application before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT1/4" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR200-08 filter regulator on its own.

AirTAC GFC200-08 Combination Unit (GFC20008F1T) FAQ

AirTAC publishes flow for the G series as curves rather than a single rated figure, so we do not quote a number. Tell us your application and we will confirm the datasheet and flow curve for this 200-size set on request, including how it compares with the 300, 400 and 600 sizes.

F1 is the gauge code: an embedded square gauge with an MPa scale. The 20008 part of the code sets the 200 size and 1/4 inch NPT port, and this version uses the default differential-pressure drain with a 40 um element. You can order automatic drain (A), manual drain (M), a 5 um element (W), other gauge scales, or a reverse/check valve (K) - ask us for the exact variant.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GFC200-08 Combination Unit (GFC20008F1T)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GFC20008F1T and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.