verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GFC200 · Two-Unit Set (filter regulator + lubricator)

AirTAC GFC200-08 Combination Unit (GFC20008F1WT)

The AirTAC GFC200-08 Combination Unit (GFC20008F1WT) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/4" ports, a 5 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizePT1/4"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$59.60 $67.10Save 11% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GFC200-08 drain, gauge and thread option on one page All GFC200-08 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GFC200-08 Combination Unit (GFC20008F1WT)

The AirTAC GFC20008F1WT is a two-unit air-treatment set pairing a filter regulator with a separate lubricator, fitted with the W code 5 um filter element for finer particulate removal than the standard 40 um grade. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes.

This is a genuine AirTAC part. The G series two-unit sets come in sizes 200, 300, 400 and 600 with drain, element, gauge and thread options. Max working pressure is 1.0 MPa (145 psi), operating temperature is -5 to 70 C (non-freezing), and the regulator range with this differential-pressure drain is 0.15-0.9 MPa (20-130 psi). Flow is published as curves, so we confirm the datasheet figures on request.

AirTAC GFC200-08 Combination Unit (GFC20008F1WT) Technical Specifications

ModelAirTAC GFC200-08 Combination Unit (GFC20008F1WT)
SeriesGFC200 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizePT1/4" (NPT thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — square, MPa scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GFC200-08 Combination Unit (GFC20008F1WT)

GFC200G-series two-unit set, 200 body — sets the port range.
08Port size PT1/4". This body offers 06 = PT1/8", 08 = PT1/4".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR200-08 filter regulator and GL200-08 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC200 · PT1/4" · 5 µm
One size upGFC300
Three-unit equivalentGC200-08
Build orderFilter regulator first, lubricator last

Where the AirTAC GFC200-08 Combination Unit (GFC20008F1WT) Is Used

science

Lab automation air supply

Conditions the air feeding pipettes, valves and small actuators on laboratory automation equipment, where the 5 um element keeps finer particulate out of sensitive pneumatic components.

view_module

Electronics assembly pick-and-place

Feeds the vacuum ejectors and gripper cylinders of an SMT or electronics assembly line, combining fine filtration, stable regulated pressure and oil mist for the actuators in one two-unit set.

air

Air bearing and low-friction actuator feed

Prepares supply air for low-friction pneumatic slides and air-driven spindles on light-duty automation, where a 5 um element upstream helps protect close-tolerance moving parts.

Is the AirTAC GFC200-08 Combination Unit (GFC20008F1WT) the Right Set?

Choose this W code when your valves or instruments need finer filtration: the 5 um element removes finer particulate than the standard 40 um. The 200 size with 1/4 inch NPT port suits lighter line duties - step to 300/400/600 for larger ports and flow. Drain is differential-pressure here; pick A for automatic or M for manual (manual widens the regulator range to 0.05-0.9 MPa / 7-130 psi). The F1 gauge is the embedded square type in MPa - alternative scales are available. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes.

Because flow is published as curves and not a single rating, ask us to confirm sizing against your application before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT1/4" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR200-08 filter regulator on its own.

AirTAC GFC200-08 Combination Unit (GFC20008F1WT) FAQ

AirTAC publishes flow for the G series as curves rather than a single rated figure, so we do not state a number or a percentage. We will confirm the datasheet and the flow curves for this 200-size, 1/4 inch port set on request so you can size it against your line demand.

Pick W when the downstream equipment - precision valves, instruments, ejectors or close-tolerance actuators - needs finer particulate removal than general plant air. The rest of the code stays the same: 200 size, 1/4 inch NPT port, differential-pressure drain, embedded square MPa gauge, and an optional K check valve if you need one.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GFC200-08 Combination Unit (GFC20008F1WT)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GFC20008F1WT and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.