The AirTAC GFC200-08 Combination Unit (GFC20008MC1TK) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/4" ports, a 40 µm element, a manual drain and regulation over 0.05 - 0.9 MPa (7 - 130 psi).
GFC20008MC1TK is a genuine AirTAC G-series two-unit set: a filter-regulator plus a separate lubricator, giving filtered, regulated and lubricated compressed air in one assembly. This configuration is size 200 with a NPT1/4 port, uses the standard 40 um filter element and a manual drain, carries an external round gauge with an MPa scale, and has the reverse (check) valve fitted so a drop in upstream pressure does not bleed the set downstream setting away. Both bowls are polycarbonate. Medium is compressed air only, maximum working pressure is 1.0 MPa (145 psi), and operating temperature is -5 to 70 C, non-freezing. With manual draining, the regulator adjust range is 0.05-0.9 MPa (7-130 psi).
AirTAC builds the GFC family in sizes 200, 300, 400 and 600 with drain, filter-grade, gauge, thread and check-valve options; This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Flow is published as curves rather than a single rating, so ask us to confirm the datasheet figures for your application before ordering.
| Model | AirTAC GFC200-08 Combination Unit (GFC20008MC1TK) |
|---|---|
| Series | GFC200 two-unit set |
| Composition | Filter regulator + lubricator (2 units) |
| Port size | PT1/4" (NPT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.05 - 0.9 MPa (7 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Manual drain |
| Bowl material | PC |
| Pressure gauge | Fitted — round, MPa scale |
| Reflux valve | Fitted (reverse flow permitted) |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFC200 | G-series two-unit set, 200 body — sets the port range. |
|---|---|
| 08 | Port size PT1/4". This body offers 06 = PT1/8", 08 = PT1/4". |
| M | Drain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| C | Gauge shape: Round. C is round, F is square. |
| 1 | Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| K | Reverse-flow (reflux) valve fitted. |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR200-08 filter regulator and GL200-08 lubricator.
A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.
| This model | GFC200 · PT1/4" · 40 µm |
|---|---|
| One size up | GFC300 |
| Three-unit equivalent | GC200-08 |
| Build order | Filter regulator first, lubricator last |
Supplying safety clamps and holding cylinders on a machining fixture, where the fitted check valve keeps downstream pressure and lubrication intact if the plant supply sags.
Feeding impact wrenches and tyre-cage rigs in a vehicle workshop, with filtered, regulated, lubricated air, a visible MPa gauge and manual bowl draining on the service round.
Running diverters and pusher cylinders on a parcel sortation module, with the check valve holding gate positions through compressor cycling and the lubricator servicing the rams.
Size 200 with a NPT1/4 port matches circuits sized to the 200 frame; step to 300, 400 or 600 for larger ports and more flow. The K code fits a reverse (check) valve - useful where an upstream pressure dip must not dump the regulated downstream circuit. The manual drain (M) suits tended installations and widens the adjust range to 0.05-0.9 MPa (7-130 psi); automatic and differential-pressure drain versions are available. The 40 um element is standard, with W giving 5 um. The C1 gauge is an external round type on an MPa scale; psi, bar and the embedded square gauge are alternatives. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. G and NPT are order options.
Flow appears in the datasheet only as curves, not as one rated figure, so send us your line pressure and air demand and we will confirm sizing before you order.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR200-08 filter regulator on its own.
AirTAC publishes flow for the G series as curves rather than a single rated figure, so there is no single rating to quote. Give us your inlet pressure, port size and downstream demand and we will confirm the datasheet curve and correct sizing before you order.
K means a reverse (check) valve is fitted in this filter-regulator, so a drop in upstream pressure does not bleed the regulated downstream circuit back through the unit. It is useful on clamp and holding circuits. If you do not need it, the plain GFC20008MC1 without the check valve is the matching set.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.