The AirTAC GFC200-08 Combination Unit (GFC20008MC3T) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/4" ports, a 40 µm element, a manual drain and regulation over 0.05 - 0.9 MPa (7 - 130 psi).
GFC20008MC3T is a genuine AirTAC G-series two-unit air preparation set: a filter regulator paired with a lubricator as a matched two-piece assembly. It removes water and particulate from compressed air, holds downstream pressure at a set level, and adds an oil mist for valves, cylinders and air tools. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Maximum working pressure is 1.0 MPa (145 psi), the manual-drain regulator adjusts from 0.05 to 0.9 MPa (7-130 psi), and operating temperature is -5 to 70 C (non-freezing). Flow is published as curves rather than a single rated figure, so we confirm datasheet numbers on request.
| Model | AirTAC GFC200-08 Combination Unit (GFC20008MC3T) |
|---|---|
| Series | GFC200 two-unit set |
| Composition | Filter regulator + lubricator (2 units) |
| Port size | PT1/4" (NPT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.05 - 0.9 MPa (7 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Manual drain |
| Bowl material | PC |
| Pressure gauge | Fitted — round, bar scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFC200 | G-series two-unit set, 200 body — sets the port range. |
|---|---|
| 08 | Port size PT1/4". This body offers 06 = PT1/8", 08 = PT1/4". |
| M | Drain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| C | Gauge shape: Round. C is round, F is square. |
| 3 | Gauge scale: bar. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR200-08 filter regulator and GL200-08 lubricator.
A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.
| This model | GFC200 · PT1/4" · 40 µm |
|---|---|
| One size up | GFC300 |
| Three-unit equivalent | GC200-08 |
| Build order | Filter regulator first, lubricator last |
Feeds the clamping cylinders on a machining cell with filtered, pressure-regulated and lubricated air, so fixtures hold at a steady set pressure while the mist protects directional valves and cylinder seals.
Conditions the air feeding glue heads, sorting gates and vacuum generators on a carton-forming line, with the manual drain letting an operator bleed accumulated water at shift start.
Installed at a bench drop serving impact wrenches and ratchets: water and rust particles are stripped out, working pressure is held at the gauge setting, and every tool pass receives oil mist.
Start by matching the 200 size and its 1/4 inch NPT ports to your line: larger G-series sizes (300, 400, 600) carry bigger ports and more flow, so step up if demand outgrows 1/4 inch. The bowl drain is manual on this code; automatic and differential-pressure versions are available if you cannot rely on someone bleeding the bowl. This set filters to the standard 40 um grade - the W suffix gives 5 um - and reads pressure on a round bar gauge; square gauges with MPa, psi or bar scales can be ordered instead.
Thread is three thread types (NPT on this code). Flow for the G-series is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR200-08 filter regulator on its own.
AirTAC publishes G-series flow as curves rather than a single rated figure, so we do not quote a number here. Send us your line pressure and downstream demand and we will confirm the sizing from the datasheet before you order.
The M in the code means the bowl is drained by hand, which suits points where an operator is on site. If the set sits where nobody can bleed it regularly, order the automatic-drain version instead; the differential-pressure drain is the catalogue default.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.