AirTAC GFC200-08 Combination Unit (GFC20008MLC1WTK)

The AirTAC GFC200-08 Combination Unit (GFC20008MLC1WTK) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/4" ports, a 5 µm element, a manual drain and regulation over 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizePT1/4"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade5 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$74.53 $82.03Save 9% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GFC200-08 drain, gauge and thread option on one page All GFC200-08 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GFC200-08 Combination Unit (GFC20008MLC1WTK)

GFC20008MLC1WTK is an AirTAC G-series two-unit set that pairs a filter-regulator with a lubricator, so a single NPT1/4 connection delivers filtered, regulated and lubricated compressed air. The 200-size body carries a manual-drain bowl and a 5 um (W) filter element for finer particle capture, while the L code makes it the low-pressure type. A round external pressure gauge reading in MPa is fitted, together with a reverse (check) valve specified by the K code.

This is a genuine AirTAC part. The G series is available in 200, 300, 400 and 600 sizes with 1/8 in to 1 in ports, with options for automatic or differential-pressure drains, 40 um or 5 um elements, square or round gauges on MPa, psi or bar scales, and three thread types (NPT on this code). Maximum inlet pressure is 1.0 MPa (145 psi) and operating temperature is -5 to 70 C. Flow is published as curves rather than a single rating, so we confirm datasheet figures on request.

AirTAC GFC200-08 Combination Unit (GFC20008MLC1WTK) Technical Specifications

ModelAirTAC GFC200-08 Combination Unit (GFC20008MLC1WTK)
SeriesGFC200 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizePT1/4" (NPT thread)
Filtering grade5 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeFitted — round, MPa scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GFC200-08 Combination Unit (GFC20008MLC1WTK)

GFC200G-series two-unit set, 200 body — sets the port range.
08Port size PT1/4". This body offers 06 = PT1/8", 08 = PT1/4".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR200-08 filter regulator and GL200-08 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC200 · PT1/4" · 5 µm
One size upGFC300
Three-unit equivalentGC200-08
Build orderFilter regulator first, lubricator last

Where the AirTAC GFC200-08 Combination Unit (GFC20008MLC1WTK) Is Used

settings_input_component

Packaging-line pick-and-place modules

Feeds the cylinders and grippers on a carton-forming station with filtered, regulated and lubricated air at a single NPT1/4 take-off, with the 5 um element protecting small pilot valves.

build

Assembly-bench air tools

Supplies impact drivers, ratchets and nutrunners at a manual assembly bench, where the lubricator keeps an oil mist in the tool air and the regulator holds a steady working pressure.

valve

Pneumatic clamping fixtures on a CNC machining center

Regulates and lubricates the air feeding swing clamps and support cylinders on a fixture, with the manual drain bled during normal setup rounds.

Is the AirTAC GFC200-08 Combination Unit (GFC20008MLC1WTK) the Right Set?

Start with the port step: this 200-size set is threaded NPT1/4; if your circuit uses 3/8 in to 1/2 in ports or heavier air demand, step up to the 300 or 400 size, since larger sizes carry larger ports and more flow. The M code fits a manual drain, so someone must bleed the bowl; if the set sits where it is not regularly visited, order the same configuration with an automatic or differential-pressure drain. The W element filters to 5 um instead of the standard 40 um. The round external gauge reads MPa; square gauges and psi or bar scales are catalogue options. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. The L suffix selects the low-pressure type, and the catalogue adjustment range for the manual-drain version is 0.05-0.9 MPa (7-130 psi) - ask us to confirm the low-pressure setting limit for your circuit. AirTAC publishes flow as curves, not one rated figure, so have us check sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/4" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR200-08 filter regulator on its own.

AirTAC GFC200-08 Combination Unit (GFC20008MLC1WTK) FAQ

AirTAC publishes G-series flow as curves, not as a single rated figure, so we do not quote a number on the page. Send us your line pressure, downstream demand and acceptable pressure drop, and we will confirm the correct size and the flow figures from the datasheet before you order.

The W code selects the finer 5 um element instead of the standard 40 um, which suits circuits with sensitive cylinders, piloted valves or precision air tools. Both grades are catalogue options across the GFC series, so the same size is also available with the standard 40 um element if your application does not need finer filtration.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GFC200-08 Combination Unit (GFC20008MLC1WTK)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GFC20008MLC1WTK and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.