verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GFC200 · Two-Unit Set (filter regulator + lubricator)

AirTAC GFC200-08 Combination Unit (GFC20008MNT)

The AirTAC GFC200-08 Combination Unit (GFC20008MNT) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/4" ports, a 40 µm element, a manual drain and regulation over 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizePT1/4"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade40 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeNot fitted
  • ThreadNPT
$52.20 $59.70Save 12% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GFC200-08 drain, gauge and thread option on one page All GFC200-08 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GFC200-08 Combination Unit (GFC20008MNT)

The AirTAC GFC series is a two-piece air-treatment set: a filter regulator (which removes water and particulate and sets downstream pressure in one body) paired with a separate lubricator that adds an oil mist to the air line. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes.

This is a genuine AirTAC part. The G series is offered in sizes 200, 300, 400 and 600 (larger size means larger port and more flow), with a choice of 40 um standard or 5 um fine filtration, differential-pressure, automatic or manual drains, gauge options, and three thread types (NPT on this code). Published flow data appears as curves rather than a single rating, so we confirm flow and datasheet figures for your application on request. Order code GFC20008MNT has NPT ports (the T in the code) for North American pipe fittings.

AirTAC GFC200-08 Combination Unit (GFC20008MNT) Technical Specifications

ModelAirTAC GFC200-08 Combination Unit (GFC20008MNT)
SeriesGFC200 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizePT1/4" (NPT thread)
Filtering grade40 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeNot fitted
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GFC200-08 Combination Unit (GFC20008MNT)

GFC200G-series two-unit set, 200 body — sets the port range.
08Port size PT1/4". This body offers 06 = PT1/8", 08 = PT1/4".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
NNo pressure gauge (N).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR200-08 filter regulator and GL200-08 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC200 · PT1/4" · 40 µm
One size upGFC300
Three-unit equivalentGC200-08
Build orderFilter regulator first, lubricator last

Where the AirTAC GFC200-08 Combination Unit (GFC20008MNT) Is Used

conveyor_belt

Air supply to conveyor diverters and stoppers

Feeding the cylinders on a packaging conveyor's diverters and stop stations, this set cleans the supply, holds a stable working pressure and oils the actuators; the manual drain suits an end-of-shift check.

handyman

Maintenance-shop air drops for hand tools

On a maintenance shop's 1/4 in drops serving impact wrenches and air ratchets, the filter regulator removes water and sets tool pressure while the lubricator keeps tool motors fed with oil mist.

factory

General plant FRL for small pneumatic panels

Installed as the point-of-entry treatment on a small machine's pneumatic panel, this two-unit set protects downstream valves and cylinders across the whole machine; the 40 um element handles general plant air.

Is the AirTAC GFC200-08 Combination Unit (GFC20008MNT) the Right Set?

This 200-size unit carries a 1/4 in NPT port; step up to 300, 400 or 600 when your line needs more flow. The manual drain means periodic operator draining - pick automatic (A) or the differential-pressure default for lines that run unattended. The standard 40 um element is the everyday choice for general pneumatic supply; specify W for a 5 um fine element. No gauge is fitted on this variant; gauge and scale choices exist on other codes. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes.

Because flow is published as curves rather than one rated figure, ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/4" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR200-08 filter regulator on its own.

AirTAC GFC200-08 Combination Unit (GFC20008MNT) FAQ

AirTAC publishes flow for the G series as curves rather than a single rated number, so we do not state one here. Share your application and required flow and we will confirm the figures from the datasheet for this 200-size, 1/4 in unit on request.

The M in the code means the filter bowl is drained manually by an operator, and the regulator's adjustment range is 0.05-0.9 MPa (7-130 psi) on this drain type. Automatic (A) and the differential-pressure default are available on other GFC codes if you prefer unattended draining.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GFC200-08 Combination Unit (GFC20008MNT)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GFC20008MNT and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.