verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GFC300 · Two-Unit Set (filter regulator + lubricator)

AirTAC GFC300-10 Combination Unit (GFC30010AC3T)

The AirTAC GFC300-10 Combination Unit (GFC30010AC3T) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT3/8" ports, a 40 µm element, a automatic drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizePT3/8"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainAutomatic drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$94.26 $101.76Save 7% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GFC300-10 drain, gauge and thread option on one page All GFC300-10 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GFC300-10 Combination Unit (GFC30010AC3T)

GFC30010AC3T is a genuine AirTAC G-series two-unit set combining a filter regulator with a lubricator, so one purchase covers filtration, pressure regulation and oil-mist lubrication of compressed air. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Maximum working pressure is 1.0 MPa (145 psi); with automatic drain the regulator adjusts across 0.15-0.9 MPa (20-130 psi), and the operating temperature range is -5 to 70 C, non-freezing.

This is a genuine AirTAC part from the G series, available in 200, 300, 400 and 600 sizes with manual, automatic or differential-pressure drains, optional 5 um fine filtration, gauge scales in MPa, psi or bar, and three thread types (NPT on this code). Flow is published by AirTAC as curves rather than one rated value, so we confirm datasheet and flow figures for your line on request.

AirTAC GFC300-10 Combination Unit (GFC30010AC3T) Technical Specifications

ModelAirTAC GFC300-10 Combination Unit (GFC30010AC3T)
SeriesGFC300 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizePT3/8" (NPT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeAutomatic drain
Bowl materialPC
Pressure gaugeFitted — round, bar scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GFC300-10 Combination Unit (GFC30010AC3T)

GFC300G-series two-unit set, 300 body — sets the port range.
10Port size PT3/8". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
ADrain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
3Gauge scale: bar. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR300-10 filter regulator and GL300-10 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC300 · PT3/8" · 40 µm
One size downGFC200
One size upGFC400
Three-unit equivalentGC300-10
Build orderFilter regulator first, lubricator last

Where the AirTAC GFC300-10 Combination Unit (GFC30010AC3T) Is Used

valve

Pneumatic valve manifold feed

Placed upstream of a solenoid valve manifold controlling plant actuators: the 40 um element and regulator protect and condition the supply while the lubricator oils the downstream air consumers.

local_shipping

Truck dock door actuators

Fitted on the air supply to loading-dock door and leveller cylinders, where the automatic drain copes with condensate from outdoor mains and the bar gauge matches the site's existing gauges.

settings_input_component

Automated test bench supply

Installed at the inlet of a pneumatic test bench, giving technicians a regulated, lubricated and filtered supply with visible bar-scale pressure for repeatable test set-ups.

Is the AirTAC GFC300-10 Combination Unit (GFC30010AC3T) the Right Set?

The 300 size with a 3/8 in port suits mid-range air demand; move to 200 for compact drops or to 400/600 where the flow curves demand larger piping. This code's automatic drain removes condensate without operator attention, and the round bar-scaled gauge suits shops that read pressure in bar; select MPa or psi scales on other codes if that is your house standard. Filtration here is the standard 40 um element - step to a W-suffixed code for 5 um if you protect fine pneumatic valves. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes.

Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT3/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR300-10 filter regulator on its own.

AirTAC GFC300-10 Combination Unit (GFC30010AC3T) FAQ

No single rated flow is quoted for this set because AirTAC publishes performance as flow curves. Tell us your inlet pressure and the demand of the equipment it feeds and we will confirm the correct size from the datasheet on request.

The default bowl drain is differential-pressure operated; A in the code selects the automatic drain, which ejects collected condensate without manual intervention. Note the regulator adjustment range differs by drain type: with automatic drain it is 0.15-0.9 MPa (20-130 psi), while manual-drain versions adjust from 0.05 MPa.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GFC300-10 Combination Unit (GFC30010AC3T)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GFC30010AC3T and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.