verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GFC300 · Two-Unit Set (filter regulator + lubricator)

AirTAC GFC300-10 Combination Unit (GFC30010AF1TK)

The AirTAC GFC300-10 Combination Unit (GFC30010AF1TK) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT3/8" ports, a 40 µm element, a automatic drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizePT3/8"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainAutomatic drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$109.19 $116.69Save 6% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GFC300-10 drain, gauge and thread option on one page All GFC300-10 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GFC300-10 Combination Unit (GFC30010AF1TK)

This GFC300-10A-F1TK is AirTAC's two-unit air preparation set - filter regulator plus lubricator - with a reverse-flow (check) valve fitted in the set for circuits where air must not pass back toward the supply. It is the 300 size with NPT 3/8 in. ports, an automatic drain on the filter bowl, the standard 40 um element and the embedded square gauge reading in MPa. The regulator adjusts from 0.15-0.9 MPa (20-130 psi) at up to 1.0 MPa (145 psi) inlet; medium is compressed air, temperature range is -5 to 70 C (non-freezing), and both bowls on this 300 size are polycarbonate (PC).

This is a genuine AirTAC part. The K option is a catalogue variant of the GFC two-unit set, which also comes without the check valve, with differential-pressure or manual drains, 40 um standard or 5 um (W) elements, embedded square or external round gauges in MPa, psi or bar scales, and three thread types (NPT on this code). Flow is published as curves rather than a single rating, so ask us to confirm sizing and datasheet figures for your application.

AirTAC GFC300-10 Combination Unit (GFC30010AF1TK) Technical Specifications

ModelAirTAC GFC300-10 Combination Unit (GFC30010AF1TK)
SeriesGFC300 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizePT3/8" (NPT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeAutomatic drain
Bowl materialPC
Pressure gaugeFitted — square, MPa scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GFC300-10 Combination Unit (GFC30010AF1TK)

GFC300G-series two-unit set, 300 body — sets the port range.
10Port size PT3/8". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
ADrain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR300-10 filter regulator and GL300-10 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC300 · PT3/8" · 40 µm
One size downGFC200
One size upGFC400
Three-unit equivalentGC300-10
Build orderFilter regulator first, lubricator last

Where the AirTAC GFC300-10 Combination Unit (GFC30010AF1TK) Is Used

bolt

Pneumatic clamping fixtures

Prepares the supply to clamp-and-hold fixtures on a machining cell, with the fitted reverse-flow (check) valve specified for circuits where air must not flow back toward the upstream side.

conveyor_belt

Conveyor diverters and stopper stations

Feeds the cylinders that divert, stop and index product on conveyor lines, combining a 40 um filter, a set regulated pressure and a lubricator mist in one two-unit set with automatic condensate drain.

factory

Machine-shop drop-leg air points

A prepared-air drop on the shop manifold for vises, air chucks and small actuators, with the check-valve option where the branch must stay isolated from backflow in the header.

Is the AirTAC GFC300-10 Combination Unit (GFC30010AF1TK) the Right Set?

Choose the 300 size with 3/8 in. NPT ports for medium-size lines; step to 200 for compact points or to 400/600 for larger ports and more flow. The K code adds the reverse-flow (check) valve - pick it when the circuit must not push air back toward the supply, otherwise order the plain F1 variant. Drain is automatic here, so condensate is ejected without operator attention; manual and differential-pressure drains are the other choices. Element is the standard 40 um; the W code gives 5 um. The embedded square gauge reads MPa, with psi/bar scales and an external round gauge as options.

Flow for the G series is published as curves, not a single rating, so tell us your application's flow and pressure and we will confirm sizing against the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT3/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR300-10 filter regulator on its own.

AirTAC GFC300-10 Combination Unit (GFC30010AF1TK) FAQ

The G-series flow data is published as performance curves, not as a single rated figure, so we do not quote a number here. Give us your required flow and working pressure and we will confirm the size and provide the datasheet on request before you order.

It marks a reverse-flow (check) valve fitted in the set, selected for circuits where air must not pass back toward the supply. Everything else decodes the same as the plain F1: 300 size, NPT 3/8 in. ports, automatic drain, 40 um element and the embedded square MPa gauge.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GFC300-10 Combination Unit (GFC30010AF1TK)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GFC30010AF1TK and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.