The AirTAC GFC300-10 Combination Unit (GFC30010AF3T) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT3/8" ports, a 40 µm element, a automatic drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).
GFC30010AF3T is a genuine AirTAC two-unit air-treatment set from the G300 series: a filter-regulator combined with a lubricator in one assembly, cleaning compressed air, holding a set downstream pressure and delivering oil mist to the connected equipment. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Maximum inlet pressure is 1.0 MPa (145 psi); with the automatic drain specified, the regulator adjusts from 0.15 to 0.9 MPa (20-130 psi). Operating temperature is -5 to 70 C (non-freezing).
It is one size within AirTAC's G series, which spans 200 to 600 with ports from 1/8 to 1 inch, three thread types (NPT on this code), differential-pressure, automatic or manual drains and 5 um optional filtration. Flow appears in the catalogue as curves rather than a single rated figure, so we confirm datasheet numbers and sizing on request.
| Model | AirTAC GFC300-10 Combination Unit (GFC30010AF3T) |
|---|---|
| Series | GFC300 two-unit set |
| Composition | Filter regulator + lubricator (2 units) |
| Port size | PT3/8" (NPT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Automatic drain |
| Bowl material | PC |
| Pressure gauge | Fitted — square, bar scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFC300 | G-series two-unit set, 300 body — sets the port range. |
|---|---|
| 10 | Port size PT3/8". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| A | Drain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 3 | Gauge scale: bar. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR300-10 filter regulator and GL300-10 lubricator.
A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.
| This model | GFC300 · PT3/8" · 40 µm |
|---|---|
| One size down | GFC200 |
| One size up | GFC400 |
| Three-unit equivalent | GC300-10 |
| Build order | Filter regulator first, lubricator last |
Conditions the air feeding mould core-pull cylinders, with regulated pressure and oil mist for the actuator valves.
Filters and regulates the branch feeding small, fast-cycling press cylinders and keeps them lubricated.
Sits upstream of rack-and-pinion actuator solenoid valves, giving clean, set-pressure, oil-misted air to the quarter-turn actuators.
The G300 frame with its 3/8 inch port suits mid-size branch lines; size up or down through G400 and G200 as your flow demand dictates. This code specifies automatic drain; differential-pressure is the default and manual (M) is the other option. Filtration is the 40 um standard element, with 5 um on the W code. The pressure gauge here is the square type scaled in bar; MPa and psi scales are alternate order codes. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes.
Since AirTAC states flow only as curves, ask us to verify the sizing against your application before you place the order.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR300-10 filter regulator on its own.
AirTAC publishes flow for this set as characteristic curves rather than one rated number, so no single figure appears here. Provide your working pressure and required consumption and we will confirm the datasheet curves and suitability on request.
This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. They are orderable specifications on the same unit, so tell us which thread your pipework uses and we will decode the right variant.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.