verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GFC300 · Two-Unit Set (filter regulator + lubricator)

AirTAC GFC300-10 Combination Unit (GFC30010ALF1T)

The AirTAC GFC300-10 Combination Unit (GFC30010ALF1T) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT3/8" ports, a 40 µm element, a automatic drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizePT3/8"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainAutomatic drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$94.26 $101.76Save 7% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GFC300-10 drain, gauge and thread option on one page All GFC300-10 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GFC300-10 Combination Unit (GFC30010ALF1T)

The AirTAC GFC30010ALF1T is a two-unit air preparation set: a filter-regulator plus a lubricator. The L marks the low-pressure regulator type, for circuits that run well below standard shop pressure, with an adjusting range up to 0.4 MPa. The filter section removes water and particulate to the standard 40 um grade and its automatic drain clears condensate unattended, while the lubricator meters oil mist into the regulated air for downstream cylinders and tools. The 300 size carries NPT3/8 ports, and the regulator has an embedded square gauge scaled in MPa.

This is a genuine AirTAC part. The G series is made in 200, 300, 400 and 600 sizes with ports from 1/8 to 1 inch, and this set can alternatively be ordered with the 5 um W filter element, a manual or differential-pressure drain, a round external gauge with MPa, psi or bar scale, the standard-pressure regulator type, and G (BSPP) or NPT threads. Flow is published as curves rather than a single rating, so ask us to confirm sizing and the datasheet for your application.

AirTAC GFC300-10 Combination Unit (GFC30010ALF1T) Technical Specifications

ModelAirTAC GFC300-10 Combination Unit (GFC30010ALF1T)
SeriesGFC300 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizePT3/8" (NPT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeAutomatic drain
Bowl materialPC
Pressure gaugeFitted — square, MPa scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GFC300-10 Combination Unit (GFC30010ALF1T)

GFC300G-series two-unit set, 300 body — sets the port range.
10Port size PT3/8". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
ADrain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR300-10 filter regulator and GL300-10 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC300 · PT3/8" · 40 µm
One size downGFC200
One size upGFC400
Three-unit equivalentGC300-10
Build orderFilter regulator first, lubricator last

Where the AirTAC GFC300-10 Combination Unit (GFC30010ALF1T) Is Used

view_module

Electronics assembly pick-and-place benches

Low-pressure grippers on an electronics bench need a supply dialed well below shop pressure. This two-unit set filters the air, holds the reduced setting and oils the small cylinders, with the embedded square gauge giving a quick pressure check at a glance.

conveyor_belt

Bottling line low-pressure capper actuators

Capper and sorter cylinders on a bottling line run at reduced pressure to protect containers. The set delivers filtered, regulated, lubricated air to those actuators while the automatic drain handles condensate in a humid environment.

science

Laboratory sample-handling actuators

Automated sample transport in a laboratory uses small cylinders at modest pressures. The low-pressure regulator keeps the supply within safe limits while the filter and lubricator keep the actuators clean and smooth-running.

Is the AirTAC GFC300-10 Combination Unit (GFC30010ALF1T) the Right Set?

Use the 300/NPT3/8 size for 3/8 inch plumbing and mid-range demand; step down to 200 for compact panels or up to 400 and 600 for larger ports. Select this L (low-pressure) type when the circuit runs at reduced pressure, with adjusting range up to 0.4 MPa; otherwise order the standard type. The 40 um element is the standard grade, with the 5 um W variant available. The automatic drain suits unattended or hard-to-reach installations; manual and differential-pressure drains are the other options. The embedded square MPa gauge keeps the set compact; a round external gauge in MPa, psi or bar scale can be substituted. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Because flow is published as curves, not a single rating, ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT3/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR300-10 filter regulator on its own.

AirTAC GFC300-10 Combination Unit (GFC30010ALF1T) FAQ

Flow for the AirTAC G series is published as curves, not as a single rated figure, so there is no single number to quote. Tell us your working pressure and air demand and we will confirm sizing against the datasheet curves on request.

The F in GFC30010ALF1T specifies an embedded square gauge, here scaled in MPa, which keeps the set compact. The C variant is a round external gauge, available with MPa, psi or bar scale. Both read the regulated downstream pressure; pick the style that suits your panel layout.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GFC300-10 Combination Unit (GFC30010ALF1T)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GFC30010ALF1T and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.