AirTAC GFC300 · Two-Unit Set (filter regulator + lubricator)

AirTAC GFC300-10 Combination Unit (GFC30010ALF1WT)

The AirTAC GFC300-10 Combination Unit (GFC30010ALF1WT) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT3/8" ports, a 5 µm element, a automatic drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizePT3/8"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainAutomatic drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$94.26 $101.76Save 7% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GFC300-10 drain, gauge and thread option on one page All GFC300-10 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GFC300-10 Combination Unit (GFC30010ALF1WT)

GFC30010ALF1WT is an AirTAC G-series two-unit set for compressed air: a filter regulator and a separate lubricator mounted as one preparation station. This configuration is size 300 with 3/8 in NPT ports, a 5 um filter element, an automatic drain on the filter bowl, and the low-pressure (L) regulator type with an embedded square gauge scaled in MPa. Maximum working pressure is 1.0 MPa (145 psi), the bowls are PC (polycarbonate) as is standard for the 300 size, and the working temperature range is -5 to 70 C (non-freezing).

The set covers filtration, pressure regulation and oil-mist lubrication in two matched bodies. Across the G series AirTAC offers sizes 200, 300, 400 and 600, ports from 1/8 in to 1 in, three thread types (NPT on this code), 40 um or 5 um filter grades, differential-pressure, automatic or manual drains, and square or round gauges in MPa, psi or bar scales. Flow is published as curves rather than a single rating, so ask us to confirm sizing and request the datasheet for this exact model.

AirTAC GFC300-10 Combination Unit (GFC30010ALF1WT) Technical Specifications

ModelAirTAC GFC300-10 Combination Unit (GFC30010ALF1WT)
SeriesGFC300 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizePT3/8" (NPT thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeAutomatic drain
Bowl materialPC
Pressure gaugeFitted — square, MPa scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GFC300-10 Combination Unit (GFC30010ALF1WT)

GFC300G-series two-unit set, 300 body — sets the port range.
10Port size PT3/8". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
ADrain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR300-10 filter regulator and GL300-10 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC300 · PT3/8" · 5 µm
One size downGFC200
One size upGFC400
Three-unit equivalentGC300-10
Build orderFilter regulator first, lubricator last

Where the AirTAC GFC300-10 Combination Unit (GFC30010ALF1WT) Is Used

precision_manufacturing

CNC fixture clamping

Supplies the air clamps that hold workpieces on a machining centre fixture: the 5 um element protects the clamp valve, the lubricator mists the clamp cylinder, and the low-pressure regulator suits light clamping circuits.

conveyor_belt

Packaging line seal cylinders

Feeds the cylinders that drive heat-seal jaws and case-flap pushers on a carton packaging line; the automatic drain clears condensate from long compressor runs without a daily bowl check.

valve

Pneumatic manifold supply, bottling hall

Conditions the air feeding a bank of directional valves that index bottles and operate fill-head actuators, with the square MPa gauge giving the line setter a direct pressure reference.

Is the AirTAC GFC300-10 Combination Unit (GFC30010ALF1WT) the Right Set?

Work through the real choices in order: size and port against air demand (this model is size 300 with 3/8 in NPT ports; 200, 300, 400 and 600 step up in port and flow), filter grade (5 um here, 40 um as the standard grade), and drain type (automatic here, with differential-pressure as the family default and manual where bowls are checked routinely). The L code makes this the low-pressure regulator type; standard automatic-drain units in the series adjust 0.15-0.9 MPa (20-130 psi), and we will confirm the low-pressure adjustment range on request.

The embedded square gauge on this model is scaled in MPa; psi (2) or bar (3) scales and an external round gauge are order options. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Because AirTAC publishes flow as curves rather than a single rating, ask us to check this model against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT3/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR300-10 filter regulator on its own.

AirTAC GFC300-10 Combination Unit (GFC30010ALF1WT) FAQ

AirTAC publishes G-series flow as performance curves in the datasheet, not as a single rated figure, so we do not quote one number here. Send us your line pressure and air demand and we will confirm this model against the curve and provide the datasheet on request.

The 5 um element removes finer particles ahead of precision valves, gauges and cylinders; 40 um is the standard grade for general circuit protection. This model carries the 5 um element, and both grades can be ordered across the G series.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GFC300-10 Combination Unit (GFC30010ALF1WT)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GFC30010ALF1WT and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.