The AirTAC GFC300-10 Combination Unit (GFC30010C1WTK) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT3/8" ports, a 5 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).
The AirTAC GFC series is a two-unit air treatment set: a filter regulator plus a separate lubricator, covering filtration, regulation and oil-mist lubrication in one package. This GFC300-10C1WTK is the 300 size with NPT3/8 ports, a differential-pressure drain, fine 5 um filtration (W), the round external MPa gauge, and the K option fitting a reverse/check valve in the regulator section.
This is a genuine AirTAC part for compressed air only. The GFC family runs from 200 to 600 sizes with choices of drain type, filtration grade, gauge and thread (NPT on this code). Flow is published as curves rather than a single rating, so we confirm datasheet figures and sizing on request.
| Model | AirTAC GFC300-10 Combination Unit (GFC30010C1WTK) |
|---|---|
| Series | GFC300 two-unit set |
| Composition | Filter regulator + lubricator (2 units) |
| Port size | PT3/8" (NPT thread) |
| Filtering grade | 5 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — round, MPa scale |
| Reflux valve | Fitted (reverse flow permitted) |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFC300 | G-series two-unit set, 300 body — sets the port range. |
|---|---|
| 10 | Port size PT3/8". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| C | Gauge shape: Round. C is round, F is square. |
| 1 | Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar. |
| W | Filtering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| K | Reverse-flow (reflux) valve fitted. |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR300-10 filter regulator and GL300-10 lubricator.
A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.
| This model | GFC300 · PT3/8" · 5 µm |
|---|---|
| One size down | GFC200 |
| One size up | GFC400 |
| Three-unit equivalent | GC300-10 |
| Build order | Filter regulator first, lubricator last |
A two-unit set feeding pilot-air manifolds on process valve actuation skids, with 5 um filtration for sensitive pilot valves and the check valve guarding against backflow.
Conditioning air to pick-and-place actuator modules on an electronics assembly machine, keeping the regulated circuit clean, lubricated and protected from reverse flow.
Supplying fine-filtered, regulated and lubricated air to nozzle and air-blow stations on a production line where upstream supply dips must not backfeed the circuit.
This variant combines two options: the W suffix for 5 um filtration instead of the 40 um standard, and the K suffix for a fitted reverse/check valve in the regulator. Size (200/300/400/600) determines port and flow capacity - the 300 with 3/8 ports suits mid-range circuits. Drain is differential-pressure here (automatic A or manual M are orderable) and C1 specifies the round external gauge with MPa scale. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes.
Since flow is published only as curves and not a single rating, ask us to confirm this unit's sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR300-10 filter regulator on its own.
AirTAC publishes flow for this series as curves rather than a single rated figure, so there is no one number to quote. Share your working pressure and air demand with us and we will confirm the datasheet figures and check this 3/8-port size against your application before you order.
W selects the fine 5 um filtration element in place of the standard 40 um, and K fits a reverse/check valve in the regulator section so flow passes one way only. The base set remains a two-unit GFC: filter regulator plus lubricator, 300 size, NPT3/8, differential-pressure drain and round MPa gauge.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.