verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GFC300 · Two-Unit Set (filter regulator + lubricator)

AirTAC GFC300-10 Combination Unit (GFC30010MNT)

The AirTAC GFC300-10 Combination Unit (GFC30010MNT) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT3/8" ports, a 40 µm element, a manual drain and regulation over 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizePT3/8"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade40 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeNot fitted
  • ThreadNPT
$73.16 $80.66Save 9% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GFC300-10 drain, gauge and thread option on one page All GFC300-10 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GFC300-10 Combination Unit (GFC30010MNT)

GFC30010MNT is an AirTAC G-series two-unit air-treatment set: a filter regulator plus a lubricator, without a pressure gauge (N). It removes water and particulate from compressed air, regulates downstream pressure and adds oil mist for the cylinders and air tools downstream. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Max working pressure is 1.0 MPa (145 psi); with manual drain the regulator adjustment range is 0.05-0.9 MPa (7-130 psi). Operating temperature is -5 to 70 C, non-freezing. At size 300 the bowls on both the filter regulator and the lubricator are PC (polycarbonate).

This is a genuine AirTAC part. The GFC two-unit family is also available in 200, 400 and 600 sizes, with a choice of ports, differential-pressure or automatic drain, a finer 5 um (W) element option, gauges included or omitted, square or round gauges in MPa, psi or bar scales, and a reverse/check valve. Because rated flow is published as curves rather than a single figure, ask us to confirm flow and datasheet figures for your application on request.

AirTAC GFC300-10 Combination Unit (GFC30010MNT) Technical Specifications

ModelAirTAC GFC300-10 Combination Unit (GFC30010MNT)
SeriesGFC300 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizePT3/8" (NPT thread)
Filtering grade40 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeNot fitted
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GFC300-10 Combination Unit (GFC30010MNT)

GFC300G-series two-unit set, 300 body — sets the port range.
10Port size PT3/8". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
NNo pressure gauge (N).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR300-10 filter regulator and GL300-10 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC300 · PT3/8" · 40 µm
One size downGFC200
One size upGFC400
Three-unit equivalentGC300-10
Build orderFilter regulator first, lubricator last

Where the AirTAC GFC300-10 Combination Unit (GFC30010MNT) Is Used

local_shipping

Fleet workshop air ring main

Filtering, regulating and lubricating the air feeding impact guns and tyre tools off a workshop ring main in a truck and trailer fleet depot.

handyman

Joinery shop nailers

Supplying conditioned, oil-mist lubricated air to the framing nailers and staplers on benches in a joinery and cabinet shop.

conveyor_belt

Distribution centre diverters

Running the pneumatic diverters and pusher cylinders that sort parcels on conveyor lines in a distribution centre.

Is the AirTAC GFC300-10 Combination Unit (GFC30010MNT) the Right Set?

The decodable choices: size and port (300 with NPT3/8; step to 200, 400 or 600 to follow the machine's air demand, larger sizes giving larger ports and more flow); drain type (manual M on this set, versus the differential-pressure default or automatic A); filter grade (standard 40 um here - choose the W suffix if you need the finer 5 um element); gauge (omitted with N; other codes add square or round gauges with MPa, psi or bar scales); This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. and the standard versus L low-pressure regulator type. Flow is published as curves, not a single rating, so ask us to confirm sizing from the datasheet against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT3/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR300-10 filter regulator on its own.

AirTAC GFC300-10 Combination Unit (GFC30010MNT) FAQ

There is no single rated flow to quote: AirTAC publishes GFC flow as curves rather than one number. Tell us the flow and pressure your line needs and we will confirm the correct size from the datasheet on request.

This set carries the standard 40 um element, which suits general plant air feeding cylinders, valves and air tools. If the downstream equipment needs finer filtration, order the W variant of the same code for the 5 um element; This order code has NPT ports (the T in the code); the PT and G versions are separate order codes.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GFC300-10 Combination Unit (GFC30010MNT)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GFC30010MNT and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.