verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GFC300 · Two-Unit Set (filter regulator + lubricator)

AirTAC GFC300-15 Combination Unit (GFC30015AC1WT)

The AirTAC GFC300-15 Combination Unit (GFC30015AC1WT) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/2" ports, a 5 µm element, a automatic drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizePT1/2"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainAutomatic drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$94.26 $101.76Save 7% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GFC300-15 drain, gauge and thread option on one page All GFC300-15 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GFC300-15 Combination Unit (GFC30015AC1WT)

The AirTAC GFC series is a two-unit air preparation set: a filter-regulator plus a lubricator, so one connection removes water and particulate, regulates downstream pressure and meters an oil mist for tools and actuators. This GFC30015 configuration is size 300 with NPT1/2 ports, an automatic drain on the filter bowl, a fine 5 um filter element (W suffix) and an external round pressure gauge on an MPa scale. The regulator adjusts from 0.15 to 0.9 MPa (20-130 psi), maximum working pressure is 1.0 MPa (145 psi), and the temperature range is -5 to 70 C, non-freezing.

This is a genuine AirTAC part. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. On size 300 the bowls are PC (polycarbonate). Flow is published as curves, not a single rated number; ask us and we will confirm the datasheet figures for your application on request. Order code GFC30015AC1WT has NPT ports (the T in the code) for North American pipe fittings.

AirTAC GFC300-15 Combination Unit (GFC30015AC1WT) Technical Specifications

ModelAirTAC GFC300-15 Combination Unit (GFC30015AC1WT)
SeriesGFC300 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizePT1/2" (NPT thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeAutomatic drain
Bowl materialPC
Pressure gaugeFitted — round, MPa scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GFC300-15 Combination Unit (GFC30015AC1WT)

GFC300G-series two-unit set, 300 body — sets the port range.
15Port size PT1/2". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
ADrain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR300-15 filter regulator and GL300-15 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC300 · PT1/2" · 5 µm
One size downGFC200
One size upGFC400
Three-unit equivalentGC300-15
Build orderFilter regulator first, lubricator last

Where the AirTAC GFC300-15 Combination Unit (GFC30015AC1WT) Is Used

view_module

Electronics assembly pick-and-place

Conditions the air feeding pick-and-place gantries and vacuum ejector circuits on an electronics line, with the 5 um element guarding small pilot valves against fine particle carryover.

settings_input_component

Automated test-rig control valves

Prepares air for a bank of solenoid valves and small actuators on an automated test rig: 5 um filtration for the valve train, steady regulated pressure, and lubrication for recurring cylinder strokes.

science

Laboratory automation pneumatics

Supplies lab automation platforms - plate handlers, grippers, lifting cylinders - with filtered, regulated and lubricated air, and the automatic drain keeps the bowl clear between unattended runs.

Is the AirTAC GFC300-15 Combination Unit (GFC30015AC1WT) the Right Set?

Size 300 with 1/2 inch ports fits circuits with meaningful air demand; move to size 200 for lighter duty or size 400/600 for larger ports and more flow. Drain: automatic (A) clears condensate unattended; choose manual (M) for supervised bowls or the differential-pressure default where intermittent blowdown is acceptable. The W suffix selects the 5 um element instead of the standard 40 um - the right call where pilot valves or sensitive actuators sit downstream. Gauge is the external round type on an MPa scale (C1); choose C2 for psi. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Because G-series flow is published as curves rather than one rating, share your demand profile with us and we will confirm sizing from the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR300-15 filter regulator on its own.

AirTAC GFC300-15 Combination Unit (GFC30015AC1WT) FAQ

We do not quote a single rated flow because AirTAC publishes G-series performance as flow curves, not one number. Give us your line pressure and required consumption and we will confirm the datasheet curve data for this two-unit set on request.

Choose W when downstream equipment - pilot-operated valves, small cylinders, ejectors - is sensitive to fine particles; the standard 40 um element suits general shop-air protection. Both grades are catalogue options on this family, and the drain, gauge and thread choices are independent of the grade.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GFC300-15 Combination Unit (GFC30015AC1WT)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GFC30015AC1WT and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.