The AirTAC GFC300-15 Combination Unit (GFC30015AC3TK) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/2" ports, a 40 µm element, a automatic drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).
The AirTAC GFC combines a filter-regulator body with a separate lubricator in one two-unit set, covering filtration, pressure regulation and oil-mist lubrication together. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. With automatic drain, the regulator adjusts 0.15-0.9 MPa (20-130 psi) and maximum working pressure is 1.0 MPa (145 psi). The 300-size bowl is polycarbonate.
This is a genuine AirTAC part from the G series, which runs from size 200 to 600 with ports from 1/8 inch to 1 inch in three thread types (NPT on this code). Flow is published only as curves with no single rated figure, so we confirm flow and datasheet details on request. Order code GFC30015AC3TK has NPT ports (the T in the code) for North American pipe fittings.
| Model | AirTAC GFC300-15 Combination Unit (GFC30015AC3TK) |
|---|---|
| Series | GFC300 two-unit set |
| Composition | Filter regulator + lubricator (2 units) |
| Port size | PT1/2" (NPT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Automatic drain |
| Bowl material | PC |
| Pressure gauge | Fitted — round, bar scale |
| Reflux valve | Fitted (reverse flow permitted) |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFC300 | G-series two-unit set, 300 body — sets the port range. |
|---|---|
| 15 | Port size PT1/2". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| A | Drain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| C | Gauge shape: Round. C is round, F is square. |
| 3 | Gauge scale: bar. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| K | Reverse-flow (reflux) valve fitted. |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR300-15 filter regulator and GL300-15 lubricator.
A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.
| This model | GFC300 · PT1/2" · 40 µm |
|---|---|
| One size down | GFC200 |
| One size up | GFC400 |
| Three-unit equivalent | GC300-15 |
| Build order | Filter regulator first, lubricator last |
Air preparation for clamping or gripper circuits where the fitted reverse valve helps hold downstream pressure if the main supply is cut, protecting the workpiece during a cycle.
A machine-mounted air panel on automated test or assembly fixtures, combining filtration, regulation, lubrication and a check valve in one 1/2 inch NPT supply point.
Supplying pneumatic functions on machine tools such as tool-clamp and chip-clearing cylinders, with the automatic drain handling condensate during long production runs.
Choose the size step (200/300/400/600) to match the pipe and air demand - here 300 at NPT1/2. Drain: this model is automatic; manual and differential-pressure drains are the other catalogue options. Filter grade: 40 um standard, 5 um with the W variant. Gauge: external round, bar scale here; square-gauge scales are also offered. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. The K suffix adds the reverse (check) valve - pick it when the circuit must hold pressure if supply is interrupted.
Flow is published as curves, not a single rating, so ask us to confirm sizing for your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR300-15 filter regulator on its own.
We do not quote a single rated flow because AirTAC publishes G-series flow as curves rather than one number. Send us your demand and we will confirm the curve data and full datasheet figures for this 300-size, 1/2 inch NPT set on request.
K fits a reverse (check) valve, so air does not flow back upstream - useful where downstream pressure should be held during a supply interruption. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.