AirTAC GFC300 · Two-Unit Set (filter regulator + lubricator)

AirTAC GFC300-15 Combination Unit (GFC30015AF1WTK)

The AirTAC GFC300-15 Combination Unit (GFC30015AF1WTK) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/2" ports, a 5 µm element, a automatic drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizePT1/2"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainAutomatic drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$109.19 $116.69Save 6% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GFC300-15 drain, gauge and thread option on one page All GFC300-15 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GFC300-15 Combination Unit (GFC30015AF1WTK)

The AirTAC GFC series is a two-unit air preparation set: a filter-regulator plus a separate lubricator working as one matched pair, so compressed air is filtered, regulated and oil-mist lubricated before it reaches your cylinders, valves and tools. This GFC300-15AF1WTK is size 300 with NPT1/2 ports, automatic drain on the filter bowl, the finer 5 um (W) filter element, an embedded square gauge reading in MPa, and a reverse (check) valve fitted to hold downstream pressure. Maximum working pressure is 1.0 MPa (145 psi), the regulator adjusting range with automatic drain is 0.15-0.9 MPa (20-130 psi), and the operating temperature is -5 to 70 C, non-freezing. At size 300, both bowls are polycarbonate (PC).

This is a genuine AirTAC part. The GFC series is offered in sizes 200, 300, 400 and 600, with 40 um standard or 5 um (W) filter elements, differential-pressure, automatic or manual drains, square or round gauges in MPa, psi or bar scales, and three thread types (NPT on this code). Flow is published as curves rather than a single rated figure, so ask us to confirm datasheet figures and sizing for your application before ordering.

AirTAC GFC300-15 Combination Unit (GFC30015AF1WTK) Technical Specifications

ModelAirTAC GFC300-15 Combination Unit (GFC30015AF1WTK)
SeriesGFC300 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizePT1/2" (NPT thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeAutomatic drain
Bowl materialPC
Pressure gaugeFitted — square, MPa scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GFC300-15 Combination Unit (GFC30015AF1WTK)

GFC300G-series two-unit set, 300 body — sets the port range.
15Port size PT1/2". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
ADrain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR300-15 filter regulator and GL300-15 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC300 · PT1/2" · 5 µm
One size downGFC200
One size upGFC400
Three-unit equivalentGC300-15
Build orderFilter regulator first, lubricator last

Where the AirTAC GFC300-15 Combination Unit (GFC30015AF1WTK) Is Used

factory

Textile weaving machine actuation

Cleaned, regulated and lubricated air drives the shed-change and selvedge cylinders on weaving machines, with the check valve helping isolate the machine's circuit from fluctuations on the shared mill air ring.

engineering

Press-shop pneumatic clamping fixtures

The set conditions supply air for the clamp and ejector cylinders on stamping-press fixtures, where the 5 um element protects pilot valves and the check valve helps hold clamping pressure against supply dips.

local_shipping

Trailer brake-test rig supply

Filtered, regulated and lubricated air feeds workshop rigs that exercise trailer air components, with the reverse valve preventing backflow from the rig into the shop distribution main.

Is the AirTAC GFC300-15 Combination Unit (GFC30015AF1WTK) the Right Set?

Size 300 with 1/2 in. ports is the mid-range step of the GFC ladder: step down to 200/300 with 1/8-1/4 in. ports for compact machines, or up to 400/600 with 3/4-1 in. ports for higher-demand headers. The automatic drain expels collected condensate without operator attention; manual-drain versions open up the wider 0.05-0.9 MPa regulator range. The W code fits the 5 um element in place of the 40 um standard for finer protection, and the K code adds a reverse (check) valve for circuits where you want the set to block backflow. The square gauge is embedded and reads MPa; psi or bar scales and a round external gauge are orderable. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. a mounting bracket is optional.

Because AirTAC publishes flow as performance curves rather than one rated number, we do not quote a flow figure here. Send us your air demand and we will confirm sizing from the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR300-15 filter regulator on its own.

AirTAC GFC300-15 Combination Unit (GFC30015AF1WTK) FAQ

AirTAC publishes flow for the G series as performance curves rather than a single rated figure, so we do not quote a number on this page. Send us your required flow and working pressure and we will confirm from the datasheet whether size 300 at 1/2 in. ports, with the 5 um element and check valve fitted, is correctly sized for your application.

The trailing K means a reverse (check) valve is fitted, so the set blocks backflow from the downstream side. Choose this version where a supply interruption must not let air drain back through the unit, and leave the K off where the circuit already handles that elsewhere. Everything else in the code is unchanged: size 300, NPT1/2, automatic drain, 5 um element and MPa-scale square gauge.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GFC300-15 Combination Unit (GFC30015AF1WTK)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GFC30015AF1WTK and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.