The AirTAC GFC300-15 Combination Unit (GFC30015ANTK) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/2" ports, a 40 µm element, a automatic drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).
GFC30015ANTK is a genuine AirTAC G-series two-unit set combining a filter-regulator and a lubricator in two pieces that mount together, so the compressed air is filtered, regulated and lubricated in one pass. The K suffix adds a reverse (check) valve to the regulator section. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. bowls are polycarbonate at this size, with a maximum working pressure of 1.0 MPa (145 psi) and an operating range of -5 to 70 C (non-freezing).
It belongs to AirTAC's G series across sizes 200 to 600, and this automatic-drain version adjusts from 0.15 to 0.9 MPa (20-130 psi). Flow is published as performance curves rather than a single rating, so ask us and we will confirm the datasheet figures for your application.
| Model | AirTAC GFC300-15 Combination Unit (GFC30015ANTK) |
|---|---|
| Series | GFC300 two-unit set |
| Composition | Filter regulator + lubricator (2 units) |
| Port size | PT1/2" (NPT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Automatic drain |
| Bowl material | PC |
| Pressure gauge | Not fitted |
| Reflux valve | Fitted (reverse flow permitted) |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFC300 | G-series two-unit set, 300 body — sets the port range. |
|---|---|
| 15 | Port size PT1/2". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| A | Drain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| N | No pressure gauge (N). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| K | Reverse-flow (reflux) valve fitted. |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR300-15 filter regulator and GL300-15 lubricator.
A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.
| This model | GFC300 · PT1/2" · 40 µm |
|---|---|
| One size down | GFC200 |
| One size up | GFC400 |
| Three-unit equivalent | GC300-15 |
| Build order | Filter regulator first, lubricator last |
Conditions and lubricates the air feeding weld-fixture clamps, with the built-in check valve helping hold the regulated condition if the plant supply fluctuates during spot-welding bursts.
Provides filtered, regulated and lubricated air to a bank of directional control valves on a process skid, where the check valve section supports stable upstream conditions.
Prepares air for heavy vehicle tipping and tail-lift circuits at a depot maintenance bay, combining water removal, pressure setting and oil mist for the cylinder seals.
Choose this code over the plain GFC30015AN when you want the reverse (check) valve fitted at the factory, keeping the upstream condition locked in if supply pressure dips. The 40 um element is the standard grade; add the W suffix for the 5 um option where finer filtration is needed. The automatic drain suits installations that run unattended. No gauge is included (N); an embedded square gauge or external round gauge on an MPa, psi or bar scale can be specified when ordering. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Sizing between sizes 200, 300, 400 and 600 depends on flow, and that is published as curves rather than a single rating - send us your demand and we will confirm it against the datasheet before you order.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR300-15 filter regulator on its own.
Yes. AirTAC publishes G-series flow as performance curves, not as a single rated number, so we deliberately do not state one here. Share your flow demand and working pressure and we will confirm the correct size 300 sizing from the datasheet, including the effect of the check-valve fitting.
K means a reverse (check) valve is fitted in the regulator section of the filter-regulator. The same set is available without it as GFC30015AN. Everything else in the code - size 300, NPT1/2 ports, automatic drain, 40 um element, no gauge - is identical between the two.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.